4. Troubleshooting
4.8. Adjusting the DADF skew
1) Stand the DADF unit. Loosen 4 screws securing the
right hinge unit slightly.
2) Adjust the position of the DADF hinge as the skew
status.
a) If the skew image is like a below sample, adjust
the hinge unit upward. (1 scale => 0.9 mm skew
adjustment)
b) If the skew image is like a below sample, adjust
the hinge unit down. (1 scale => 0.9 mm skew
adjustment)
3) Detach the DADF sponge after adjusting the skew.
Place the DADF sponge on platen glass. And then close
the DADF unit to stick the sponge.
4-223