4. Troubleshooting
4.4.5.4. Adjustment
Print Adjustment
•
Diagnostics > Adjustment > Print Adjustment > Automatic Adjustment
Purpose
To correct image position of print-outs automatically.
Operation Procedure
1) Press “Paper Supply” button and select a tray.
2) Press “Paper Size” button and select a paper size of the previously selected tray.
3) Press “Print” button. A test pattern will be printed out.
4) Press “Next” button. The system ask to locate the test pattern.
5) Locate the front side of Scanner A/S Chart at the scanner glass .
NOTE
DADF cannot be used.
6) Press “OK” button. Automatic scanning will occur .
7) Locate the back side of Scanner A/S Chart at the scanner glass again and press “OK” button
once more.
8) The system will automatically calculate the proper value based on scanning result of the
test pattern.
9) The new values are set to the system.
Verification
Print out and check if all the position of scale marks (a, b, e, f) in the image are located within the
specified limit.
Specification
a, b, e, f : 10 mm, ± 1.5 mm
Reference
Scanner A/S Chart
■ Scanner A/S Chart
Front Side
Back Side
Copyright© 1995-2016 SAMSUNG. All rights reserved.