4. Troubleshooting
► Error Code
H1-5330
► Error message
DCF Failure #H1-5330. Check internal DCF connection.
► Symptom
A communication error between the optional tray and the main machine has occurred.
► Troubleshooting method
1) Lift up and release the DCF unit from the machine.
2) Remove the Bracket Rear Cover after removing 6 screws.
3) Check if the interface connector is connected to the DCF board. If the interface connector(
JC39–01690A
) is
defective, replace it.
4) If the problem persists, replace the DCF board.
(
Refer to 3.3.33.1. DCF Main Board
)