4. Troubleshooting
► Error Code
S5–3111
► Error message
UI System Failure #S5-3111:Turn off then on.
► Symptom
Communication error between main board and OPE board has occurred.
► Troubleshooting method
1) Remove the rear cover.
(
Refer to 3.3.2 Rear Cover
)
2) Check if the OPE cable is connected to the main board correctly.
3) Remove and disassemble the OPE Unit.
(
Refer to 3.3.6 OPE Unit
)
4) Check if the OPE cable is connected to the OPE board correctly.
5) If the connection is OK, replace the main board(
JC92–02429A
).
Copyright© 1995-2016 SAMSUNG. All rights reserved.