4. Troubleshooting
► Error Code
C3–4110
► Error message
Prepare new cyan imaging unit
► Symptom
Cyan drum unit has almost reached the end of its life.
► Troubleshooting method
1) Order new cyan drum unit because drum unit with level of “Low” will be exhausted soon.
► Error Code
C3–4130
C3–4140
► Error message
End of life, Replace with new magenta imaging unit
► Symptom
Cyan drum unit is at the end of its life.
► Troubleshooting method
1) Open the front cover.
2) Remove the waste toner container.
3) Remove the cyan drum unit.
(
Refer to 3.2.2.1. Drum Unit
)
4) Install the new cyan drum unit(
CLT-R809
).
5) Clean the LSU window.
(
Refer to 3.2.1.2. Cleaning the LSU window
)
6) Install the waste toner container.
7) Close the front cover.
4-105