8 | SAMLEX AMERICA INC.
SECTION 3 |
Operation
3.0 GENERAL INFORMATION
EVO-RC-PLUS Remote Control provides the user with the ability to monitor the operation and also to modify EVO™
Inverter/Charger’s operating parameters. The default settings in EVO™ Inverter/Charger are adequate for some
installations but may have to be modified for others. This Section provides details on the remote functions, status and
menu maps and displays, fault messages and parameter settings.
3.1 NAVIGATING THE REMOTE
Please refer to the layout at Fig. 1.1.
• LCD Display (1)
– The 4-line (20 characters each) LCD display shows status and information for the EVO™
Inverter/Charger. All Setup Menus and faults also appear on the LCD display.
The level of brightness / dimming of the LCD backlight can be programmed to suit user preference.
(See Section
4.9 for details)
• ON/OFF Key (2)
– The On/Off Key is used for switching on/ switching off the EVO™ Inverter/Charger and also to
enter/exit Standby Mode.
• Navigation Keys (5, 6, 7, 8)
– These four keys allow simple access to Menu Item that assists configuring,
monitoring, and troubleshooting the EVO™ Inverter/Charger.
o
Navigation Key Functions:
•
Back
– Return to previous selection
•
Up
– Scroll from lower to upper Menu Screen in various Menu Maps e.g. Fig 3.1 (a)
•
Down
– Scroll from upper to lower Menu Screen in various Menu Maps e.g. Fig 3.1(a)
•
Enter
– Select/write a particular value or option.
• Status
– Blue LED indicator for indicating operating status
(see details at Section 6, Table 6.1)
.
• Fault
– Red LED indicator for indicating fault conditions
(see details at Section 6, Table 6.1)
.
• SD Card slot
– This slot supports SD memory card
(up to 32GB, FAT16/32)
. The SD Card is used for data
logging of EVO™ Inverter/Charger’s operational statistics and events and saving and uploading of programmed
parameters. See Section 5: SD Card.
Содержание EVO-RC-PLUS
Страница 127: ...SAMLEX AMERICA INC 127 NOTES ...