106 | SAMLEX AMERICA INC.
SECTION 4 |
Parameter Setup
4.8.2.11 PARAMETER SAVE
(Table 4.9, (i) Parameter Setup Screen No. 10 under Column 1 (ii) Parameter Setup Screen No. 11 under Column 2)
Save all parameters to SD Card.
(See Details at Section 5.4)
4.8.2.11.1 Programming Steps for Parameter "PARAMETER SAVE"
ð
ð
E V O - 1 2 1 2 F
I n v e r t i n g
A C
o u t p u t :
1 2 0 . 0 V
< 0 . 1 0 A
6 0 . 0 0 H z
Enter Key
Any Operating Mode Screen from
Fig 3.1 to 3.8
[Above screen is Screen 1 of Fig 3.2(a)]
Password 8052
See Section 4.3.1
For programming options, see Table 4.9:
• Screen No.10 (Column 1) for
EVO-1212F/1212F-HW/1224F/1224F-HW
• Screen No.11 (Column 2) for
EVO-2212/2212E/3012/3012E/2224/2224E/4024
/4024E & EVO-4248SP
S e l e c t
G r o u p
*
C H A R G E
C U R V E
ð
S e l e c t
P a r a m e t e r
*
O T H E R
F U N C T I O N
ð
S e l e c t
P a r a m e t e r
O T H E R
F U N C T I O N
*
P O
W
E R
S A V I N G
0 = D i s a b l e
S e l e c t
P a r a m e t e r
O T H E R
F U N C T I O N
*
P A R A M E T E R
S A V E
0 = N o
Down Key x 4 times
Enter Key
P a s s w o r d
k e y
i n
0 0 0 0
ð
Enter Key
S e l e c t
P a r a m e t e r
O T H E R
F U N C T I O N
*
P A R A M E T E R
S A V E
0 = N o
ð
Enter Key
4.8.2.12 TEMP UNIT
(Table 4.9, (i) Parameter Setup Screen No. 11 under Column 1 (ii) Parameter Setup Screen No. 12 under Column 2)
Temperature display can be selected in °C or °F. Default is in °C.
4.8.2.12.1 Programming Steps for Parameter "TEMP UNIT"
ð
ð
E V O - 1 2 1 2 F
I n v e r t i n g
A C
o u t p u t :
1 2 0 . 0 V
< 0 . 1 0 A
6 0 . 0 0 H z
Enter Key
Any Operating Mode Screen from
Fig 3.1 to 3.8
[Above screen is Screen 1 of Fig 3.2(a)]
Password 8052
See Section 4.3.1
For programming options, see Table 4.9:
• Screen No.11 (Column 1) for
EVO-1212F/1212F-HW/1224F/1224F-HW
• Screen No.12 (Column 2) for
EVO-2212/2212E/3012/3012E/2224/2224E/4024/
4024E & EVO-4248SP
S e l e c t
G r o u p
*
C H A R G E
C U R V E
ð
S e l e c t
P a r a m e t e r
*
O T H E R
F U N C T I O N
ð
S e l e c t
P a r a m e t e r
O T H E R
F U N C T I O N
*
P O
W
E R
S A V I N G
0 = D i s a b l e
S e l e c t
P a r a m e t e r
O T H E R
F U N C T I O N
*
T E M P
U N I T
0 = C
Down Key x 4 times
Enter Key
P a s s w o r d
k e y
i n
0 0 0 0
ð
Enter Key
S e l e c t
P a r a m e t e r
O T H E R
F U N C T I O N
*
T E M P
U N I T
0 = C
ð
Enter Key
4.8.2.13 PASSWORD DISABLE
(Table 4.9, (i) Parameter Setup Screen No. 12 under Column 1 (ii) Parameter Setup Screen No. 13 under Column 2)
This parameter allows to disable/enable Password (
8052
) that is required to change the value of any programmable
parameter. Use of Password is recommended because it prevents accidental/unintentional change of parameter setting.
Default is enabled (
PASSWORD DISABLE set at "O=No"
).
(i) Down Key x 9 times for EVO-1212F/1212F-
HW/1224F/1224F-HW
(ii) Down Key x 10 times for EVO-2212/2212E/30
12/3012E/2224/2224E/4024/4024E
& EVO-4248SP
(i) Down Key x 10 times for EVO-1212F/1212F-
HW/1224F/1224F-HW
(ii) Down Key x 11 times for EVO-2212/2212E/30
12/3012E/2224/2224E/4024/4024E
& EVO-4248SP
Содержание EVO-RC-PLUS