66 | SAMLEX AMERICA INC.
SECTION 4 |
Parameter Setup
4.4.2.16.1 Programming Steps for Parameter “GS DETECT TIME”
ð
ð
E V O - 1 2 1 2 F
I n v e r t i n g
A C
o u t p u t :
1 2 0 . 0 V
< 0 . 1 0 A
6 0 . 0 0 H z
Enter Key
Enter Key
Any Operating Mode Screen from
Fig 3.1 to 3.8
[Above screen is Screen 1 of Fig 3.2(a)]
Password 8052
See Section 4.3.1
See Table 4.3, Parameter Setup
Screen No. 16 for
programmable range
S e l e c t
G r o u p
*
C H A R G E
C U R V E
ð
S e l e c t
P a r a m e t e r
C H A R G E
C U R V E
*
B U L K C U R R E N T
2 0 A
ð
S e l e c t
P a r a m e t e r
C H A R G E
C U R V E
*
G S
D E T E C T
T I M E
1 0
s e c
S e l e c t
P a r a m e t e r
C H A R G E
C U R V E
*
G S
D E T E C T
T I M E
1 0
s e c
Enter Key
Down Key x 15 times
P a s s w o r d
k e y
i n
0 0 0 0
ð
Enter Key
4.4.2.17 GEN ON TIME
(Table 4.3, Parameter Setup Screen No. 17)
This parameter is a Programmable Timer
(0-240min; Default: 60 min)
that is used for programming Automatic Starting
and Stopping of Generator
[Section 4.8.2.5.2.3]
. The Timer sets the duration the Generator will remain ON from
the time the Status Relay has been switched ON (energized). The Status Relay will switch ON (energize) and start the
Generator if the battery voltage remains at threshold of “LOW VOLT ALARM”
(Section 4.4.2.8)
, or lower for continuous
period = “GS DETECT TIME”
(Section 4.4.2.16)
.
4.4.2.17.1 Programming Steps for Parameter “GEN ON TIME”
ð
ð
E V O - 1 2 1 2 F
I n v e r t i n g
A C
o u t p u t :
1 2 0 . 0 V
< 0 . 1 0 A
6 0 . 0 0 H z
Enter Key
Enter Key
Any Operating Mode Screen from
Fig 3.1 to 3.8
[Above screen is Screen 1 of Fig 3.2(a)]
Password 8052
See Section 4.3.1
See Table 4.3, Parameter Setup
Screen No. 17 for
programmable range
S e l e c t
G r o u p
*
C H A R G E
C U R V E
ð
S e l e c t
P a r a m e t e r
C H A R G E
C U R V E
*
B U L K C U R R E N T
2 0 A
ð
S e l e c t
P a r a m e t e r
C H A R G E
C U R V E
*
G E N O N
T I M E
6 0 m i n
S e l e c t
P a r a m e t e r
C H A R G E
C U R V E
*
G E N O N
T I M E
6 0 m i n
Enter Key
Down Key x 16 times
P a s s w o r d
k e y
i n
0 0 0 0
ð
Enter Key
4.4.2.18 GEN OFF DELAY
(Table 4.3, Parameter Setup Screen No. 18)
This parameter is a Programmable Timer
(0-240min; Default: 60 min)
that is used for the following:
• Programming Automatic Starting and Stopping of Generator
(Section 4.8.2.5.2.2)
:
The Timer sets the
time period the batteries are required to remain charged at the desired programmed level of voltage = “RESET
VOLTAGE”
(Section 4.4.2.7)
, or higher before the Status Relay is switched OFF (de-energized) to stop the
Generator
• Programming Option "1=Option 2" in "ONLINE OPTION"
(Section 4.4.2.14)
:
The Timer sets the time period
the batteries are required to remain charged at the desired programmed level of voltage = “RESET VOLTAGE”
(Section 4.4.2.7)
, or higher before the Transfer Relay is switched OFF (de-energized) to exit “Charging” Mode and
revert to “Inverting” Mode.