4.3.1 Example of Password Activation and Changing Bulk Current Setting for EVO-1212F / 1212F-
HW from Default Value of 20A to 50A
S e l e c t
G r o u p
*
C H A R G E C U R V E
Starting from any of the 5 Operating Mode Screens
(shown at Figs
3.1 to 3.8)
, press
Enter
Key. Screen "Select Group, CHARGE CURVE"
as shown on the left will be displayed
(Parameter Group 1 of "Select
Group" Menu Map, Fig 4.1)
Press
Enter
key to access 24 Parameter Screens under "Select
Parameter" Menu Map for Parameter Group 1 "Charge Curve"
(Fig
4.2)
[Parameters are detailed at Table 4.3 under Section 4.4.1].
S e l e c t
G r o u p
*
C H A R G E C U R V E
B U L K C U R R E N T
2 0 A
Screen "BULK CURRENT, 20A" as shown on the left will be displayed
(Screen No.1 of "Select Parameter" Menu Map for Parameter Group
1: CHARGE CURVE at Fig 4.2)
. Default current setting of 20A or
previously set value will be displayed.
Press
Enter
Key to change Bulk Current parameter setting. A Password
will be requested. Password will NOT be requested if disabled - see
Section 4.3.2.
P a s w o r d k e y
i n
0 0 0 0
Password consisting of 4 digits "0000" will be requested as shown
on the left (
NOTE:
Password to be entered is 8052). The first digit
will have a blinking cursor "_". Use
Up /Down
Keys to scroll to
number 8 for the first digit “8” of the password.
Momentarily
press
Enter
Key
(
Short
press). Digit 8 will be entered as the first digit of
the Password and the blinking cursor will automatically move to the
2nd digit (0) to the right. As the next digit in the Password “8052”
is already “0”,
momentarily
press
Enter Key
(
Short
press) to enter
“0” in the second digit. The blinking cursor will automatically move
to the 3rd digit (0). Use
Up /Down Keys
to scroll to number 5 for the
3rd digit “5” of the password “8052” and
momentarily
press
Enter
Key
(
Short
press). The blinking cursor will automatically move to the
4th digit (0). Use Up /Down Keys to scroll to number 2 for the 4th
digit “2” of the password “8052”. Now keep the
Enter Key
pressed
continuously for longer time
(3 to 4 sec) to write the full password
of 4 digits i.e. “8052”.
P a s w o r d c o r r e c t
Flashes twice when Password is correct. (8052)
P a s w o r d e r r o r ! !
Flashes twice when Password is NOT correct.
SECTION 4 |
Parameter Setup