SAMLEX AMERICA INC. | 35
3.6.9 Menu Maps for Inverting Mode Screens When Inverting is Stopped by the Lithium Ion
Battery Management System (BMS)
For background information, please refer to Sections 4.4.2.22.1 & 4.4.2.22.2
Menu Maps shown in Figs 3.8(a) to 3.8(c) for various EVO
TM
models are applicable when parameter "BATTERY TYPE" is set
for option "1 = Lithium"
(See Section 4.4.2.22.1).
Screens shown below will be seen when the Battery Management
System (BMS) of Lithium Battery sends a command
(potential free contact closure signal)
to pins 4 and 5 of the RJ-45
Temperature Sensor Jack on the EVO™ Inverter/Charger
(Temperature Sensor is not required for Lithium Battery)
to
stop inverting to protect the Lithium Battery from deep discharging condition. Please see details at Section 4.4.2.22.
Menu Maps for this operating condition are shown in Figs 3.8(a) to 3.8(c).
3.6.9.1 Menu Map for Inverting Mode Screens for Models EVO-1212F/EVO-1212F-HW/EVO-1224F/EVO-1224F-
HW When Inverting is Stopped by Lithium Ion Battery Management System (BMS)
[Refer to Fig 3.8(a)]
NOTES:
1. The 1st line of the display screen shows Model No. on the left
and the Operating Mode “Inv stop by BMS” on the right. This
message is shown in two parts – first “Inv stop” and then “by
BMS”. Each part is switched every 2 sec.
2. The 2nd, 3rd and the 4th lines show various operating
parameters and their values
4. Use Up
ñ
and Down
ò
Keys to navigate to the desired screen.
Up Key
Down Key
E V O - 1 2 1 2 F
I n v S t o p
A C o u t p u t :
0 . 0 0 V
< 0 . 1 0 A
0 . 0 0 H z
Screen
No. 1
E V O - 1 2 1 2 F
I n v S t o p
A C o u t p u t :
< 1
2 W
< 1 2 V A
P F =
0 . 0 0 0
Screen
No. 2
E V O - 1 2 1 2 F
I n v S t o p
A C i n p u t :
1 2 0 . 0 V
< 0 . 1 0 A
6 0 . 0 0 H z
Screen
No. 3
E V O - 1 2 1 2 F
I n v S t o p
B a t t e r y :
1 2 . 0 0 V
0 . 0 A
E x t e r n a l :
0 . 0 A
Screen
No. 5
E V O - 1 2 1 2 F
I n v S t o p
B a t t e r y
1 2 0 . 0 0 V
H e a t
s i n k
2 5 . 0 C
T r a n s f o r m e r
2 5 . 0 C
Screen
No. 6
E V O - 1 2 1 2 F
I n v S t o p
E V O V e r :
x . x x
I D =
1
R C
V e r :
x . x x
Y Y Y Y / M M / D D H H : M M
Screen
No. 7
ð
ð
ð
ð
ð
ð
ð
ð
E V O - 1 2 1 2 F
I n v S t o p
A C i n p u t :
< 1 2
W
< 1 2 V A
P F =
0 . 0 0 0
Screen
No. 4
ð
ð
Fig 3.8(a) Menu Map for Inverting Mode
Screens for EVO-1212F/1212F-HW/1224F/1224F-
HW when Inverting is Stopped by the Lithium
Ion Battery Management System (BMS)
(Model
shown is EVO-1212F)
"Inv stop" for 2 sec
"by BMS" for 2 sec
See NOTE 1
"Inv stop" for 2 sec
"by BMS" for 2 sec
See NOTE 1
"Inv stop" for 2 sec
"by BMS" for 2 sec
See NOTE 1
ð
ð
"Inv stop" for 2 sec
"by BMS" for 2 sec
See NOTE 1
"Inv stop" for 2 sec
"by BMS" for 2 sec
See NOTE 1
SECTION 3 |
Operation
Содержание EVO-RC-PLUS