II-
23
BF-Sirius
Maintenance Manual
Symptom
Check Item
Recovery Method
The illumination
does not light off.
No response from PC.
Turn off the PC and the main breaker.
If the lights do not go off after the PCs are rebooted,
quickly turn off the main breaker and please contact Saki
Corporation.
The scan motor
does not run.
Setup file for inspection software
is corrupted.
1. Quit the inspection software.
2. In
C:\BF1\Backup
folder, select the folder with the
most recent date.
3. In the folder, copy and overwrite the files to
C:\BF1
.
The scan table
stops running.
Limit sensor is on.
Push the emergency stop switch and move the scan
table to nearby the center of its operating range.
Release the emergency stop condition and reselect the
inspection data.
Emergency stop
cannot be
released.
Emergency stop switch remains
pushed.
Turn the emergency stop switch clockwise.
The machine
doesn’t scan.
Emergency stop condition may
be on.
Release the emergency stop condition.
Refer to
3.1 Emergency Stop
in Operation Manual.
Inspection failure
due to FmaFe
abnormality.
Vertical lines can be seen in
scanned image.
Clean the shading sheet, the half mirror, the lenses,
and the diffusers.
Horizontal lines can be seen in
scanned image.
Reinsert the signal line connector from the CCD unit to
the PC.
Image sways.
Please contact Saki Corporation.
Noisy image.
Reinsert the signal line connector from the CCD unit to
the PC. Rewire the machine by isolating the LAN cables
in the machine from the signal lines leading from the
CCD unit to the PC.
The buzzer does
not stop.
Emergency stop condition may
not be released.
Release the emergency stop condition.
Refer to
3.1 Emergency Stop
in Operation Manual.
PCB drops from
the scan table.
The PCB size is different
from the guide rail width.
Adjust the guide rail width again based on the PCB
size and tighten the clamp lever again.
If the PCB drops inside the machine, push the
emergency stop switch or turn off the machine to move
the scan table manually and remove the PCB.
Clamp lever is loose.
Abnormal noise.
Foreign objects touching the
cooling fan.
Check and remove the foreign objects from the cooling
fan.
Foreign objects pinching the
scan table.
Push the emergency stop switch and stop the scan
table to remove the foreign objects.
The screws fixing the external
covers are loose.
Firmly tighten the screws fixing the external covers.
Recovery Method for Abnormal Operation
T
a
bl
e
4-1
Содержание BF-Sirius
Страница 1: ... SJ241DCM1 02E BF Sirius Manual ...
Страница 7: ...I 1 BF Sirius Operation Manual Operation Manual ...
Страница 37: ...II 1 BF Sirius Maintenance Manual Maintenance Manual ...
Страница 61: ...BF Sirius Installation Manual III 1 Installation Manual ...
Страница 65: ...BF Sirius Specification Customer Support IV 1 Specification Customer Support ...