II-
11
BF-Sirius
Maintenance Manual
1.4 Greasing-up
Maintenace Interval
Items
Procedures
Annually
Scan Ball Screw
Linear Guide
Spring Guide
With a dry soft cloth or paper, wipe off any old grease or stains.
Apply fresh grease.Wipe off any excess grease with a dry and
soft cloth or paper.
Greasing-up
T
a
bl
e
1-2
CAUTION
When applying grease, prevent foreign object being mixed into grease.
NOTE
The above Maintenance Interval is given as a standard interval, Maintenace Interval is subject to
change depending on the usage environment of the machine.
Supplier
Model
Flammable Attribution
Exchange Volume
Shin-Etsu Chemical Co., Ltd.
G-30M
Extremely Low Risk
20 cc
Applied Grease
T
a
bl
e
1-3
CAUTION
If the grease attached on your hand or body, wipe off with dry cloth or waste cloth. Afterwards rinse
with soup and flowing water. In case of grease is dropped on the floor, wipe it with a waste cloth then
spread sand and wipe it off thoroughly.
Grease up the scan ball screw and linear guide.
Step1:
Scan Ball Screw
Linear Guide
Greasing-up 1
FFFure
1-1
7
Remove the five M4 cross recessed head screws and remove the top of scan table.
Step2:
M4 cross recessed head screw
Greasing-up 2
FFFure
1-1
8
Содержание BF-Sirius
Страница 1: ... SJ241DCM1 02E BF Sirius Manual ...
Страница 7: ...I 1 BF Sirius Operation Manual Operation Manual ...
Страница 37: ...II 1 BF Sirius Maintenance Manual Maintenance Manual ...
Страница 61: ...BF Sirius Installation Manual III 1 Installation Manual ...
Страница 65: ...BF Sirius Specification Customer Support IV 1 Specification Customer Support ...