I-
26
BF-Sirius
Operation Manual
Item
Description
Rack Count :
A
/ Total
B
Indicates the specified number of total NG files (
B
) and which number in
the rack the NG PCB currently inspected (
A
). (*1)
Inspected Num
Indicates the total number of PCBs that has been inspected by AOI machine.
Current
Indicates the total number of PCBs that are judged as NG by AOI machine.
NG Window Num :
C
/ Total
D
Indicates the total number (
D
) of NG spots on the currently-inspecting
PCB and what number (
C
) NG is displayed.
Revised Window :
E
/
Not Revised
F
Indicates how many (
E
) NG spots were reviewed by operator and how
many are remaining (
F
).
NG Parts Num
G
/ Total
H
Indicates the total number (
H
) of NG components on the currently-
inspecting PCB and what number (
G
) NG component is displayed.
Reference Name :
I
-
J
Name of the component shown in image (
A
) at present. The number in
the square brackets is a lead number, such as in the case of an IC.
Inspected on
Time when the PCB was inspected.
Group Name
Name of the group to which the PCB being inspected belongs.
Board Name
Name of the PCB being inspected.
Repaired by
Name of the operator who makes judgements.
Explanation of the Area C Items
T
a
bl
e
3-4
NOTE
(*1) The number of the NG PCBs stored in one rack can be specified in
Auto Mode Setup >
Make NG files
(refer to Table 3-3
Explanation on Each Item for Auto Mode Setup
).
Item
Description
Macro Code
Indicates the component name.
NG Type :
K
[
L
]
Indicates the defect type (
K
) of the component shown in the upper right
image, and the test result (
L
).
Idle Count
Indicates the number of NG PCBs waiting for judgement, which were
scanned while judging certain PCB.
REPAIR
Press if the inspection result is NG and the PCB is indeed defective.
OK
Press if the inspection result is NG but the PCB is good.
Prev NG / Next NG
Jumps to the non-judged component.
Prev / Next
Moves to the previous or next defective spot.
NG Component
Designates NG to all the inspection items of the same component at once.
OK Component
Designates OK to all the inspection items of the same component at once.
Show Pattern
Displays the image of the first window in library registration on the upper
right of the Defective window.
All Windows
Displays all windows for that component not only the window for
defective spot on the upper right window.
Window
Displays only the defective spot windows.
Drop down list under Window
Allows user to change the defect type.
QuFt
Close
Edit NG Component Data
dialog.
Explanation of the Area D Items
T
a
bl
e
3-
5
After all the judgements are finished, the dialog shown in Figure 3-38 appears. Press
Step4:
OK
.
Edit NG Component Data
dialog closes and the next judgement is available.
Inspect
FFFure
3-3
8
NOTE
If the next PCB image was already scanned during the judgement and the result of the
PCB was NG,
Edit NG Component Data
dialog for the next PCB appears after pressing
OK
.
Содержание BF-Sirius
Страница 1: ... SJ241DCM1 02E BF Sirius Manual ...
Страница 7: ...I 1 BF Sirius Operation Manual Operation Manual ...
Страница 37: ...II 1 BF Sirius Maintenance Manual Maintenance Manual ...
Страница 61: ...BF Sirius Installation Manual III 1 Installation Manual ...
Страница 65: ...BF Sirius Specification Customer Support IV 1 Specification Customer Support ...