INITIAL START-UP
1.
Make sure the transmission
12
is in the neutral position, see operation
section under four speed transmission. New delivered machines are
shipped with the transmission in neutral. Make sure the front swing
gate guards are closed.
2.
Make sure the vacuum exit transition
9
is connected to the vacuum
housing exit transition
17
and is firmly connected with rubber hose
and clamps to the material deceleration box.
3.
Make sure that the water pump
16
suction and discharge are not
blocked to prevent damage. You can run a diaphragm pump without
water at the suction without causing damage as long as the suction
and discharge are not blocked.
4.
Plug a 120 volt light into the generator
18
receptacle. Make sure
that the light is accessible at the outside of the machine frame and
in good working condition.
5.
Start the truck and engage the PTO at a low idle in accordance with
the truck manufacturer’s literature. Check that the belt drive from under
the truck is tracking true on the idlers and that no excessive belt slap is
occurring. Shut the truck down for any belt tensioning adjustment. Once
the belts are tensioned properly, bring the truck up to the manufacturer’s
recommended speed established during installation. Always engage the
PTO at a low idle and disengage at a low idle.
6.
Once the machine (machine or PTO) is up to speed, the input/clutch
shaft and water pump at the front of the machine will be turning.
The rear gearbox and generator will be turning. The vacuum will not
come on until the electro- magnetic clutch
19
is switched on.
Do not
switch the vacuum on while the PTO is engaged.
(see step 12 for proper procedure)
7.
Turn on the master switch
4
, light indicates that the switch is on.
8.
Pull emergency stop buttons
A
&
B
out (on) and make sure
both swing gates are closed. Press the reset button
3
located
on the front panel.
9.
Plug the remote cord shipped with new delivered machines into
the receptacle
5
making sure the toggle switch is in the center (off)
position. This is a twist lock connection to prevent the cord from
being pulled out during machine operation.