LED
Identification on
the panel
Status
Meaning
Off
The module is NOT receiving power.
Solid red
The module is faulty.
Blinking green
Initialization is in progress. Continuous blinking
indicates errors.
Solid green
The module is operational
System LED
Status
Solid yellow
System temperature exceeds the alarm
temperature. The system keeps operating but
the performance is affected.
Off
The port link is NOT connected.
Solid green
The port is connected.
QSFP+ port LED
Link/ACT
Blinking
The port is transmitting and receiving data.
Specifications
Model M8600E-12QXS-DB
CPU
Quad-core CPU, each core with the clock speed of 1.0G
BOOTROM
8 MB
Flash Memory
512 MB
SDRAM
DDRIII 1 GB
Port Type
12 QSFP+ ports
Transmission
Medium
40GBASE-SR4
Multi-mode optical fiber
40GBASE-LR4 Single-mode optical fiber
40G-QSFP-STACK3M 3m QSFP+ copper cables (DAC)
LED Status,
Link/ACT
Hot Swapping
Supported
Power
Consumption
<200W
EMC Standards
GB9254-2008 CLASS A
Safety Standards
GB4943-2011
Operating
Temperature
0 to 50°C
Storage
Temperature
-40 to 70°C
Operating Humidity
10%-90% RH (non-condensing)
MTBF 382,000
hours
Weight
Net weight: 3.92 kg
Dimensions
(W x D x H)
399 mm x 440 mm x 40.18 mm
M8600E-24XS4QXS-DB
Module Appearance
Figure 1-27 Appearance of M8600E-24XS4QXS-DB Module
External Port
The M8600E-24XS4QXS-DB provides 24 SFP+ ports and four QSFP+ ports. The SFP+ ports support 10G SFP+ modules
and Gigabit SFP modules. QSFP+ ports support 40-Gigabit QSFP+ modules. Hot swapping of the
M8600E-24XS4QXS-DB, SFP, SFP+ and QSFP+ modules is supported.
Содержание RG-S8605E
Страница 1: ...RG S8600E Series Switches Hardware Installation and Reference Guide V1 09...
Страница 63: ...Figure 2 2 Preventing EMI on RG S8607E Figure 2 3 Preventing EMI on RG S8610E...
Страница 86: ...Figure 3 21 Grounding Point on the Rear of the RG S8610E Switch...
Страница 116: ...Figure 7 12 Replacing the Module for RG S8610E...
Страница 120: ...Note A Fan modules to be removed B Fan modules to be installed...
Страница 132: ......