Figure 0-3 Back Panel of the RG-S8605E Switch
Note:
System power module slots
PoE power module slots
Symbol of installation direction for the air filter
Captive screws of the air filter
Air filter module
Fan tray
Captive screws of the fan tray
⑧
Handle of the fan tray
Power supply
AC power supply input: The RG-PA1600I and the RG-PA600I power supply modules are supported. The two types
of power supply modules support power management. The supervisor module of the RG-S8605E switch can read
the power supply information and implement flexible and intelligent power management.
DC power supply input: The RG-PD1600I and the RG-PD600I power supply modules are supported. The two types
of power supply modules support power management. The supervisor module of the RG-S8605E switch can read
the power supply information and implement flexible and intelligent power management.
PoE input: The RG-PA1600I-P, RG-PA
1600I-PL and RG-PA3000I-PL
power modules are available. The power
module supports power management. The supervisor module of the RG-S8605E switch can read the power supply
information and implement flexible and intelligent power management.
The RG-S8605E switch supports 1+1 power supply redundancy to improve the system stability and reliability.
We recommend users to configure redundancy for power supply modules.
Heat Dissipation System
The operating environment temperature of the RG-S8605E switch ranges between 0 and 50°C. The thermal design must
satisfy the requirement on the device's reliability in the temperature range while ensuring the device's safety and
maintainability. According to the thermal design of the RG-S8605E switch, fans are used to draw air for forced convection
cooling in order to ensure that the device works properly in the specified environment.
Figure 0-4 Ventilation and Heat Dissipation System of the RG-S8605E Switch (Air Intakes)
Содержание RG-S8605E
Страница 1: ...RG S8600E Series Switches Hardware Installation and Reference Guide V1 09...
Страница 63: ...Figure 2 2 Preventing EMI on RG S8607E Figure 2 3 Preventing EMI on RG S8610E...
Страница 86: ...Figure 3 21 Grounding Point on the Rear of the RG S8610E Switch...
Страница 116: ...Figure 7 12 Replacing the Module for RG S8610E...
Страница 120: ...Note A Fan modules to be removed B Fan modules to be installed...
Страница 132: ......