HVDC Power
Supply
RG-PA1600I: 192 to 216 VDC, power: 1200W;
216 to 290 VDC, power: 1600W
RG-PA600I: 192 to 290 VDC, power: 600W
The power supply supports reversible HVDC.
The HVDC-supported PDU socket should be provided.
It is recommended to install a DC air switch. During power-on, turn on the DC air
switch after connecting the power cord. During power-off, turn off the DC air switch
before removing the power cord.
Power Supply
Redundancy
The power supply redundancy of the same model is supported
Fan Module
M05-FAN
EMC Standards
GB9254-2008 CLASS A
Safety Standards
GB4943-2011
Operating
Temperature
0 to 50°C
Storage
Temperature
-40 to 70°C
Operating Humidity
10%-90% RH (non-condensing)
Long term operation height: 3000m at 50
℃
. The temperature decreases by 1
℃
as the altitude
ranging from 3000m to 4000m increases by each 200m.
Operation height: 4000m max
Altitude
Storage height: 4000m max
MTBF 213,000
hours
Noise
56.6 dB at 35
℃
66 dB at 50
℃
Weight
Net weight: 20.2 kg (including the chassis and fans)
Dimensions
(W x D x H)
442 mm x 530 mm x 219.5 mm (cable management brackets excluded), 5U
442 mm x 598 mm x 219.5 mm (cable management brackets included), 5U
The weight only includes that of the empty chassis and fans. The whole device's weight is subject to that of
the modules selected.
The RG-S8605E switch is an A-class product and may cause radio disturbance to surroundings. In this case,
users are advised to take proper measures against the disturbance.
Product Appearance
The hardware system of the RG-S8605E switch is composed of the chassis, the power system, modules and the cooling
system.
The power system provides one PoE power supply slot and two system power supply slots, and supports 1+1 power
supply redundancy. Users are recommended to configure redundancy for the power supplies.
The RG-S8605E switch provides two supervisor module slots and three service module slots. The supervisor
modules support 1+1 redundancy. Users are recommended to configure redundancy for the supervisor modules.
Users may choose different service modules as needed.
The cooling system is composed of the fan trays and air filters. Fan trays are on the left side of the chassis. Air filters
are on the right side of the chassis.
Figure 0-1 Appearance of the RG-S8605E Switch
Содержание RG-S8605E
Страница 1: ...RG S8600E Series Switches Hardware Installation and Reference Guide V1 09...
Страница 63: ...Figure 2 2 Preventing EMI on RG S8607E Figure 2 3 Preventing EMI on RG S8610E...
Страница 86: ...Figure 3 21 Grounding Point on the Rear of the RG S8610E Switch...
Страница 116: ...Figure 7 12 Replacing the Module for RG S8610E...
Страница 120: ...Note A Fan modules to be removed B Fan modules to be installed...
Страница 132: ......