Run
Alarm
Fault
Solid green
Off
Off
The module is operational
Off
Off
Off
There is no power input
Blinking green Off
Off
The module is in standby mode
Solid green
Solid yellow Off
Persistent
overcurrent.
Solid green
Solid yellow
Off
Temperature alarm
Off Off
Solid
red
Over-temperature causes power-off
Off
Off
Solid red
AC is powered off.
Off
Off
Solid red
Short circuit.
Off
Off
Solid red
Output undervoltage
Off
Off
Solid red
Output overvoltage
Solid green
Off
Blinking red Communication
fails
Specifications
Module Model
RG-PA1600I-P
Rated Voltage
Range
100 to 120 VAC, 200 to 240 VAC; 50/60 Hz
Max Voltage
Range
90 to 264 VAC; 47 to 63 Hz
Max Power
Output
90 to 176 VAC Power: 1000 W
176 to 264 VAC Power: 1600 W
Weight
Net weight: 1.60 kg
Power Cord
Requirement
16A power cord
When you plug in the power cord, please fasten the anti-loose buckle to the power cord to prevent loosening.
Operation altitude: 5000m max. Storage altitude: 5000m max.
RG-PA1600I-PL
Module Appearance
Figure 0-36 Appearance of the RG-PA1600I-PL Module
Содержание RG-S8605E
Страница 1: ...RG S8600E Series Switches Hardware Installation and Reference Guide V1 09...
Страница 63: ...Figure 2 2 Preventing EMI on RG S8607E Figure 2 3 Preventing EMI on RG S8610E...
Страница 86: ...Figure 3 21 Grounding Point on the Rear of the RG S8610E Switch...
Страница 116: ...Figure 7 12 Replacing the Module for RG S8610E...
Страница 120: ...Note A Fan modules to be removed B Fan modules to be installed...
Страница 132: ......