Before inserting or removing the power module, please verify whether the switch is well mounted. The switch
is high, avoid switch tumble when you are inserting or removing the power module.
If you want to hot swap a power supply, please make sure that the interval between two operation is greater
than 30 seconds.
Please do not touch the golden finger part of the power supply which is removed after power off in case that
capacitor discharge is not full.
Install the AC power system
1)
Loosen the captive screws on the filler panel covering the power slot at the rear of the chassis.
2) Insert the power module into the slot along the rail until the rear connector of the power module stays in good contact
with the rear panel.
3) Tighten the captive screws on the power module to fix it.
Figure 3-22 Installing Power Supplies
Install the PoE power system
The PoE power system and the DC power system share the same installation steps with the AC power system.
The total power of power supplies of the RG-S8600E must be greater than the working power of the host.
Otherwise, some modules may fail to start.
The host power is the summation of the power of all working modules, including the supervisor module,
service module and fan. For the power consumption of each module, see the module specifications.
Содержание RG-S8605E
Страница 1: ...RG S8600E Series Switches Hardware Installation and Reference Guide V1 09...
Страница 63: ...Figure 2 2 Preventing EMI on RG S8607E Figure 2 3 Preventing EMI on RG S8610E...
Страница 86: ...Figure 3 21 Grounding Point on the Rear of the RG S8610E Switch...
Страница 116: ...Figure 7 12 Replacing the Module for RG S8610E...
Страница 120: ...Note A Fan modules to be removed B Fan modules to be installed...
Страница 132: ......