The air filter for the RG-S8600E shall be cleaned periodically (generally once every three months) by dry
cleaning or washing. Do not rub during the cleaning or washing and flat dry after the cleaning or washing.
Power Supply Maintenance
When the power supply fails, you only need to disconnect the power cable, loosen the two panel screws on the power
module, unplug the power module, replace it with a good one, and tighten the panel screws, and then connect the power
cables.
Replacing Fuses
To replace the old fuse wire with the correspondent new one, please contact the technical support representatives of
Ruijie Networks. The following table lists the specifications for the module fuses.
Module
Fuse Slot Number
Fuse Specification
M8600E-CM F1
F
10A/125V
F2
F
5A/125V
M8600E-24GT20SFP4XS-ED F1
F
30A/125V
M8600E-48GT-ED F2 F
30A/125V
M8600E-48GT-EF F2 F
30A/125V
M8600E-48GT-P-ED
F2, F3, F4
F 30A/125V
M8600E-44SFP4XS-ED F1
F
30A/125V
M8600E-44SFP4XS-EF F1
F
30A/125V
M8600E-08XS-ED F1 F
30A/125V
M8600E-08XS-EF F1 F
30A/125V
M8600E-48XS-DB F1 F
40A/60V
M8600E-12QXS-DB F1 F
30A/125V
M8600E-24XS4QXS-DB F1
F
40A/60V
M8600E-24GT/8SFP-EB
F1 F
30A/125V
M8600E-24SFP/8GT-EB
F1 F
30A/125V
RG-WALL 1600-B-ED
F1, F2
F 30A/125V
M18010-FE-D I
F1
F 30A/125V
M05-FAN F1
F
40A/60V
M07-FAN F1,F2
F
40A/60V
M10-FAN-R
F3, F4, F5, F6
F 5A/125V
F15
F
30A/125V
F1 F
40A/60V
M10-FAN-F
F3, F4, F5, F6, F7, F8
F 5A/125V
Содержание RG-S8605E
Страница 1: ...RG S8600E Series Switches Hardware Installation and Reference Guide V1 09...
Страница 63: ...Figure 2 2 Preventing EMI on RG S8607E Figure 2 3 Preventing EMI on RG S8610E...
Страница 86: ...Figure 3 21 Grounding Point on the Rear of the RG S8610E Switch...
Страница 116: ...Figure 7 12 Replacing the Module for RG S8610E...
Страница 120: ...Note A Fan modules to be removed B Fan modules to be installed...
Страница 132: ......