background image

SIP Ring Switch

valid for:

#57753 

 SIP Ring Switch 4xOut

Release 1.68 September 2023

Manual

Installation, Startup and Application

Содержание 57753

Страница 1: ...SIP Ring Switch valid for 57753 SIP Ring Switch 4xOut Release 1 68 September 2023 Manual Installation Startup and Application...

Страница 2: ...ny of our statements without verification Please inform us of any error or misunderstanding you come about so we can identify and eliminate it as soon as possible Carry out your work on or with W T pr...

Страница 3: ...roduct 6 2 Safety notices 7 General notices 7 Intended use 7 Electrical safety 7 EMC 8 Batteries 8 3 Quick Startup 10 Network connection 10 Supply voltage 10 IP address assignment 10 Function test 10...

Страница 4: ...ettings 19 Configuring the Outputs 19 Date Time 19 Language Info 20 Password 20 Certificates 21 8 Basic applications 22 SIP Dialing via IP telephony 22 Browser access 24 Sending email 26 9 Actions 28...

Страница 5: ...ventive actions are taken 1CAUTION Indicates a hazard that can result in slight injury if no appropriate preventive actions are taken 1NOTE Indicates a hazard which can result in equipment damage if n...

Страница 6: ...uipment may not be disposed of with normal waste but rather must be brought to a proper electrical scrap processing facility Symbols on the product Symbol Explanation CE Mark The product conforms to t...

Страница 7: ...esent manual Non intended use is any other use or any modification to the described devices Electrical safety 1WARNING Before beginning any kind of work on the SIP Ring Switch you must completely dis...

Страница 8: ...ns and the stricter emissions limits for households and small businesses Therefore there are no EMC related limitations with respect to the usability of the devices in such environments The complete D...

Страница 9: ...e clock module is located in a holder on the upper PCB After removing replacing the battery reassemble in reverse order Batteries and rechargeables must not be disposed of with normal waste recycling...

Страница 10: ...tility After starting Wutility your SIP Ring Switch appears in the device list If multiple devices are shown please identify your device by the Mac address that is printed on a white sticker at the de...

Страница 11: ...e port for initializing firmware updates are enabled DHCP is also enabled You can explicitly specify for all communication paths whether the outputs may be accessible A list of the currently open TCP...

Страница 12: ...tion access with administrator login is required Application and access possibilities SIP The core function of the SIP ring switch is to switch outputs by dialing extension numbers in an IP PBX The co...

Страница 13: ...an also access the SIP Ring Switch Actions Which output is to be switched to which state when a certain extension is called is determined by creating corresponding actions In addition actions can be c...

Страница 14: ...ion in the control cabinet or sub distribution For mechanical fixation the SIP Ring Switch should be snapped onto a 35mm top hat rail according to DIN EN 50022 In doing so the Web IO takes up 45mm in...

Страница 15: ...Reset Outputs max 4x500mA Vcc 0 1 2 3 12 24V DC 150mA Output Load Input Output Mode Check and LED Test shown on Reset Outp ON Inp ON URL ______________ 12 24V GND With a typical industrial power supp...

Страница 16: ...used as re ference ground Here is an example of the wiring of output 1 12 24V GND Last Load SIP Ring Switch 57753 Digital 4xOut Power Status Error Reset Outputs max 4x500mA VCC 0 1 2 3 12 24V DC 150m...

Страница 17: ...he network to which the SIP Ring Switch is connected an IP address should be automatically assigned to the SIP Ring Switch To be able to specifically access the SIP Ring Switch you should configure a...

Страница 18: ...ust the IP address If you select Address range any network you can also enter parameters which are different from your local network for example to pre configure the SIP Ring Switch for a different ne...

Страница 19: ...without signal and switched on in ON state By activating the inversion the output configured in this way acts exactly reversed Pulse mode By activating the Pulse Mode the output automatically returns...

Страница 20: ...can also be done here Language Info In addition to the language selection German or English further display elements including the logo can be modified here Password The passwords for administrator an...

Страница 21: ...utton the entered values are formally checked and the new key is generated The new CSR can be downloaded via the Download CSR button Self signed certificate A previously generated inidividual CSR can...

Страница 22: ...is purpose SIP access must first be activated under Communication channels SIP To register in the system the following access data must be configured in the SIP basic settings area Telephone system IP...

Страница 23: ...extension number Password Enter the password that is stored in the telephone system for the extensions repre sented by the SIP ring switch SIP type Choose here between PJSIP and SIP The added extensio...

Страница 24: ...list and the desired phone numbers or connection IDs can then be marked and added to the subscriber inventory by clicking on the Save button Output access To determine which output is to be switched...

Страница 25: ...d web pages Home The Home page provides an overview of the outputs and the configured actions With the appropriate login the outputs can be switched Both must first be enabled under Web sites Home By...

Страница 26: ...gs are necessary in order to send email messages Network parameters If you want to send via a mail server on the Internet it is important that the basic network settings are correct Check under Basic...

Страница 27: ...placed by the current IO states counter values etc when the e mail is sent Placeholder Description ox State of the outputs No x ON OFF cx Counter state No x o State of all outputs as hex bit pattern d...

Страница 28: ...calls from a shared subscriber trigger the action Output Any output can be specified as an initiator For the output you can specify whether a change from OFF to ON a change from ON to OFF or any stat...

Страница 29: ...ll hour every 15th minute and every 30th minute For example An action should be performed in the months of April to October every Monday at 8 00 a m Minute 0 Hour 8 Date Month 4 10 Day of week 1 Devic...

Страница 30: ...P Ring Switch or Web IO Digital Also in this case either one specific output or several outputs can be switched Specify the IP address of the Device at which the outputs are to be switched Specify the...

Страница 31: ...In addition to the actual message that is sent when the action is triggered a clear message can also be stored in the text messages The clear message is sent when the trigger for the action is no lon...

Страница 32: ...rates as a TCP client When initiating the action it opens a TCP connection to the specified TCP server address on the specified port transmits the message or clear text and then immediately closes the...

Страница 33: ...he supported commands and additional details on access via ASCII sockets can be found in the Web IO programming manual download at http www WuT de Follow the manual link on the data sheet page of Web...

Страница 34: ...lt this access is blocked and must first be enabled using Communication paths Web API A detailed description of the supported HTTP requests and more details about access using Web techniques such as A...

Страница 35: ...er are in the same network segment Read the Ethernet address of the SIP Ring Switch from the label at the side of the housing xxx Now use the following command line from the ARP table of the computer...

Страница 36: ...ther power or the network connection during the update All the settings in the SIP Ring Switch are retained and the SIP Ring Switch should be immediately ready to use following the update Emergency ac...

Страница 37: ...g Digital Outputs network min 1000 V Conections 1 x 11x screw terminal block for outputs and power 1 x RJ45 for network Displays Status LEDs for network Error LEDs for system and application 8 LEDs fo...

Страница 38: ...38...

Страница 39: ...39...

Страница 40: ...40 Wiesemann Theis GmbH Porschestra e 12 D 42279 Wuppertal Mail info wut de Web www wut de Tel 49 0 202 2680 110 Fax 49 0 202 2680 265...