KP-3016/KP-3016A Series
Basic Operation 61
Bosch Security Systems, Inc.
Technical Manual
F.01U.315.927
Rev. 02
Selected Color Cell and Ellipsis Button
The
Selected Color
cell displays the currently selected color of the background.
The
Ellipsis
button opens the Select Color window where you can assign a different color to the background.
Normal State Group Box
The
Normal State
group box is used when the tally is active and is not in the flash state. If there is no tally active, then the
colors are whatever is defined for the assignment in the intercom.
Enable Text Color Check Box
The
Enable Text Color
check box enables the Selected Color cell and Browse button. This means you can modify the color of
the Text displayed.
Selected Color Cell and Ellipsis Button
The
Selected Color
cell displays the currently selected color of the text.
The
Ellipsis
button opens the Select Color window where you can assign a different color to the text.
Enable Background Color Check Box
The
Enable Background Color
check box enables the Selected Color cell and Browse button. This means you can modify the
color of the Background displayed.
Selected Color Cell and Ellipsis Button
The
Selected Color
cell displays the currently selected color of the background.
The
Ellipsis
button opens the Select Color window where you can assign a different color to the background.
Enable Alternate Text Check Box and Entry Field
The
Enable Alternate Text
check box and entry field is used to enter alternate text or characters that appears intermittently
with the existing tally text.
This field can contain up to four (4) characters.
Duty Cycle Drop Down Menu
The
Duty Cycle
drop down menu is used to select the rate the tally flashes alternate with normal text mode. The flash period is
one (1) second.
Available options for this menu are:
On Solid
There is no flash
Slow 25%
The flash appears for 25% of the flash period (1/4 of a second), while the normal mode appears
for 75% of the flash period (3/4 of a second)
Slow 50%
The flash and the normal mode appear for 50% of the flash period (1/2 second each)
Fast 50%
The flash and the normal appear for 50% of the flash period in alternating pattern (1/4 second
flash, 1/4 second normal mode, 1/4 second flash, and 1/4 second normal mode)
Fast 75%
The flash appears for 75% (3/4 of a second), while the existing text appears for 25% (1/4 if a
second) of the flash period
Содержание EKP-3016
Страница 4: ...Bosch Security Systems Inc Technical Manual F 01U 315 927 Rev 02 4 KP 3016 3016A Series...
Страница 8: ...Bosch Security Systems Inc Technical Manual F 01U 315 927 Rev 02 10 KP 3016 KP 3016A Series...
Страница 64: ...66 Basic Operation KP 3016 KP 3016A Series Bosch Security Systems Inc Technical Manual F 01U 315 927 Rev 02...
Страница 82: ...84 Firmware Download KP 3016 KP 3016A Series Bosch Security Systems Inc Technical Manual F 01U 315 927 Rev 02...
Страница 134: ...136 KP 3016 3016A Menu System KP 3016 KP 3016A Series Bosch Security Systems Inc Technical Manual F 01U 315 927 Rev 02...
Страница 163: ...KP 3016 3016A Series 165 Bosch Security Systems Inc Technical Manual F 01U 315 927 Rev 02 Notes...
Страница 164: ...Bosch Security Systems Inc 12000 Portland Avenue South Burnsville MN 55337 U S A www boschcommunications com...