![Rosemount 3051S Series Скачать руководство пользователя страница 139](http://html.mh-extra.com/html/rosemount/3051s-series/3051s-series_reference-manual_1487385139.webp)
Specifications and Reference Data
131
Specifications and Reference Data
September 2017
Reference Manual
00809-0100-4803, Rev GA
Load limitations
Maximum loop resistance is determined by the voltage
level of the external power supply, as described by:
Overpressure limits
Transmitters withstand the following limits without
damage:
Static pressure limit
Rosemount 3051SMV_ _1: Differential and
Static Pressure, temperature
Rosemount 3051SMV_ _2: Differential
Pressure and Static Pressure
Operates within 0.5 psia (0,03 bar) and the values in the
table below:
Rosemount 3051SMV_ _ 3: Differential
Pressure and temperature
Rosemount 3051SMV_ _ 4: Differential
Pressure
Operates within specifications between static line pressures
of 0.5 psia and 3626 psig;
Burst pressure limits
Rosemount 3051SMV with coplanar or
traditional process flange
10000 psig (689,5 bar)
Rosemount 3051SMV Transmitter
Maximum loop resistance = 43.5
⫻
(Power supply voltage – 12.0)
The Field Communicator requires a minimum loop resistance of 250
Ω
for communication.
Rosemount 3051SMV_ _1: Differential and
Static Pressure, temperature
Rosemount 3051SMV_ _2: Differential
Pressure and Static Pressure
Static Pressure
Differential Pressure
Range 1
Range 2
Range 3
Range 3 GP/AP
1600 psi
(110,3 bar)
1600 psi
(110,3 bar)
1600 psi
(110,3 bar)
Range 4 GP/AP
2000 psi
(137,9 bar)
3626 psi
(250 bar)
3626 psi
(250 bar)
Rosemount 3051SMV_ _ 3: Differential
Pressure and temperature
Rosemount 3051SMV_ _ 4: Differential
Pressure
Range 0
750 psi (51,7 bar)
Range 1
2000 psig (137,9 bar)
Ranges 2–5
3626 psig (250,0 bar)
Option code P9
4500 psig (310,3 bar)
Option code P0 (classic only)
6092 psig (420 bar)
1322
1000
500
0
12.0
20
30
42.4
Voltage (Vdc)
Load (Ohms)
Operating
Region
Static Pressure
Differential Pressure
Range 1
Range 2
Range 3
Range 3 GP/AP
800 psi
(57,91 bar)
800 psi
(57,91 bar)
800 psi
(57,91 bar)
Range 4 GP/AP
2000 psi
(137,9 bar)
3626 psi
(250 bar)
3626 psi
(250 bar)
Option code P9
4500 psig (310,3 bar)
Option code P0 (classic only)
6092 psig (420 bar)
Range 0
0.5 psia to 750 psig
(0,03 to 51,71 bar)
Range 1
0.5 psia to 2000 psig
(0,03 to 137,9 bar)
Содержание 3051S Series
Страница 1: ...Reference Manual 00809 0100 4803 Rev GA September 2017 Rosemount 3051S MultiVariable Transmitter ...
Страница 2: ......
Страница 114: ...106 Reference Manual 00809 0100 4803 Rev GA Operation and Maintenance September 2017 Operation and Maintenance ...
Страница 126: ...118 Reference Manual 00809 0100 4803 Rev GA Troubleshooting September 2017 Troubleshooting ...
Страница 171: ...Product Certifications September 2017 Reference Manual 00809 0100 4803 Rev GA 163 Product Certifications ...
Страница 173: ...Product Certifications September 2017 Reference Manual 00809 0100 4803 Rev GA 165 Product Certifications ...
Страница 176: ...168 Product Certifications Product Certifications September 2017 Reference Manual 00809 0100 4803 Rev GA ...
Страница 180: ...172 Product Certifications Product Certifications September 2017 Reference Manual 00809 0100 4803 Rev GA CO S CO O ...
Страница 181: ...Product Certifications September 2017 Reference Manual 00809 0100 4803 Rev GA 173 Product Certifications ...
Страница 182: ...174 Product Certifications Product Certifications September 2017 Reference Manual 00809 0100 4803 Rev GA ...
Страница 184: ...176 Product Certifications Product Certifications September 2017 Reference Manual 00809 0100 4803 Rev GA ...
Страница 185: ...Product Certifications September 2017 Reference Manual 00809 0100 4803 Rev GA 177 Product Certifications ...
Страница 187: ...Product Certifications September 2017 Reference Manual 00809 0100 4803 Rev GA 179 Product Certifications ...
Страница 188: ...180 Product Certifications Product Certifications September 2017 Reference Manual 00809 0100 4803 Rev GA ...
Страница 189: ......