RP248CN User’s and Installer’s Manual Page
3
4. READY LED
The Ready LED indicates whether the system is under ready or not, and also whether
system can be armed or not.
On-- The system is ready to be armed now.
Off-- The system is not ready to be armed now.
Flicker-- The system is ready for arming, and at the same time some especial zone(s) with
entry /exit delay is triggered.
5. BYPASS LED
When BYPASS LED
on, one or more zone(s) has/have been bypassed or under stay statue.
6. FIRE LED
The LED flicker rapidly when lighting.
7. TEMPER LED
When the detector(s), the keypad or the Expansion Module is /are tempered or destroyed, a
Tamper Code report will be sent and the LED will be lighting.
8. Digit Keys
When programming, key in 0-9 digits.
Under the state of users function, quick go to the menu.
9. System Arming [ARM]
When depress [ARM] key, all the zones are armed. The LED Display delay time.
Under the user functional state, the key [ARM] is used to set data. For example, when
setting the clock, [ARM] can be used to choice the month, weekday and partition.
10. Keypad Buzzer
The buzzer
is used for indicating the entry/exit delay, alarm, door chime and so on.
11. Stay Home Arming [STAY]
When depress [STAY] key, the interior zones will not be armed. During stay arming, the
LCD display the delay time.
Under user function, the [STAY] key is used to set data. For example, when setting the
clock, [STAY] is used to choice month, weekday and partition.
12. Function Key [*]
Depress [*] Key into the function set ting state.
Back t o the anterior menu or return to the normal state.
13. Confirm Key [#]
The Key [#] used for confirm and save input data.
14. Moving Key [
←
][
→
]
Key [
←
] is used to choice the anterior command, or moving the cursor to left.
Key [
→
] is used to choice the next command, or moving the cursor to right.
15. Panic Alarm Key [1]
+
[2]
Depress [1]+[2] at least 2 seconds, the system will send a panic alarm message to CMS or
following-me numbers.
16. Fire Alarm Key [4]
+
[5]
Depress [4]+[5] at least 2 seconds, the system will send a fire alarm message to CMS or
following-me numbers.
17. Special Emergency Key[7]
+
[8]
Depress [7]+[8] at least 2 seconds, the system will send a special emergency message to
CMS or following-me numbers.