RP248CN Users and Installer’s Manual
Page 15
1—“RED” connect to RED on the main board
2—“BLK” connect to BLK on the main board
3—“YEL” connect to YEL on the main board
4—“GRN” connect to GRN on the main board
5—“S.AUX” connect to the DC12V switch power port (S.AUX) on the main board.
7/10/13/16/19/22/25/28
-
“COM” the port of common earth, which should be connected
to one port of ALARM or TEMPER on the detector(s).
6/8/9/11/12/14/15/17/18/20/21/23/24/26/27/29--“Z” should be connected to one port of
ALARM on the detector(s).
Power Supply Module (RP248EPS)
It is used for power DC12V to detectors modules and sirens and with built-in siren driver
(750mA)
1- Connect to the anode of standby battery
2- Connect to the cathode of standby battery
3- “RED” connect to RED on the main board
4- “BLK” connect to BLK on the main board
5- “YEL” connect to YEL on the main board
6- “GRN” connect to GRN on the main board
7- Tamper port of the module, which can make up a loop with the port of “BLK”
8/9- “BELL+” is to be connected with anode of the siren, “BELL-” is to be connected with
the cathode of the siren.
10- Connect to earth
11/12- AC supply input (AC16.5V)
13- Power LED indicator
14- Dial switch