RP248CN Users and Installer’s Manual
Page 21
input the installation
code .So , recovery of tamper
alarm ( and tamper LED),will
need the installation person to
deal with.
NO: Tamper alarm ( and
Tamper LED) will recovery
after resolved the trouble, do
not need the installation
person .
[2][1][9] TECH
RESET
NO
YES: After recovery of the
alarm zone , come to the
“READY” (ready state) must
input the installation code . So
need the installation person
come to deal with it
NOT READY- TECH REST
correspond LED indication
will shown on the keypad.
NOTE: before light READY
LED, all the zones must be
safe.
NO: once the alarm zone
recovery, when all the zones
are safe, READY LED will light.
[2][2][0] ABORT
ALARM
NO
YES: Alarm centre perhaps
receive a “ stop alarm” code
when alarm sent by false. If
input the right code in 90
seconds, and recovery the
alarm ,will send the original
alarm code.
NO: Once touch the alarm , will
not send “stop alarm” code
[2][2][1] SUMM/WINT
NO
YES: In spring ,(first Sunday
in April), system will adjust
inside clock by automatically,
will move up one hour every
day, and according to the
American daytime. In autumn,
( last Sunday in October),
stand back one hour
according to the Amercian
standard time.
NO : no any flexibility time
could adjust.
[2][2][2]
FORCED KSW
YES
YES: In any parts, use key
switch to arm , interference
zone(NOT READY) will
bypass automatically, parts
will show “force armed”
NO: parts could not arm by key
switch, until all the
interference(not ready)zone
recovery.
[2][2][3] PAGER
NO
When the specify event
happed in parts, user could
receive inform signal
parameter via letter and
number mini BP machine.
First , on the user operation
function , as a “Follow-Me”
(follow telephone) setting,
must programme number of
the BP machine.
YES: allow via number or
letter number BP machine,
provide increased event
information ,once the call will
through ,will send and show.
NO: only during the parts alarm
station ,call the BP machine.
Need as “Follow-me”
programme, can not increase
the standard information by
send
[2][2][4] ARM
PREWRN
NO
YES: when any parts set as
arm automatically,
225seconds before arm
automatically, will hear exit
delay (pre-alarm) counter
backwards second.
During this period, the parts
as programmed as above,
distributed keypad ,will hear
the exit delay DIDI sound.
During the any time of the
counter backwards second, if
input the efficiency user code,
automatically arm of the parts
will delay 45 minutes.
If parts have already” arm
automatically”, will disarmed
after input the efficiency user
code. Will can not arm