RP248CN Users and Installer’s Manual
Page 23
[1] ONE-BY-ONE ---
First, program set all the
data to the zone 1: zone
type, sound, terminal
features, loop response,
labels, and so on. Then
program other zones one by
one.
Note: after you finish all
zones, depress [#]. The
keypad will emits a
long ”beep--”, the data will
be saved.
[2] PARTITIONS
All the Zones
belong to one
Partition
Appoint the zone to
partition(s)
1. Without partition, the
system will appoints all
the zone to partition 1
acquiescently;
2. Each zone can be
appointed to several
partitions.
[3] ZONE
TYPE
Choice the correct zone
type, depress [#] to confirm
[3][0][0] NOT
USED
Unused zone’s type. Which
can be used to close the
zones
[3][0][1]
EX/EN 1
Zone 1
Exit/Entry delay 1
[3][0][2]
EX/EN 2
Exit/Entry delay 2
[3][0][3] EX(OP)/EN
If the zone is bypass during
the exit delays, even if the
zone is opened, the system
still can be armed
[3][0][4]
EN FOLLOW
Zone 2
There are two zones have
Exit Delay, Exit Delay 1 and
Exit Delay 2. If zone with
Exit Delay 2 has been
triggered before zone with
Exit Delay 1. The zone with
Exit Delay 1 must have
entry delay. Otherwise, the
system will alarm
immediately.
[3][0][5] Instant
The zones
except zone1
and zone2
No entry delay, it will be
triggered and alarm
immediately.
[3][0][6]
I+ EX/EN 1
Stay arm, zone will be
bypass automatically;
Arm, zone has entry/exit
delay 1
[3][0][7]
I+ EX/EN 2
Stay arm, zone will be
bypass automatically;
Arm, zone has entry/exit
delay 2
[3][0][8] I+
EX(OP)/EN
Stay arm, zone will be
bypass automatically;
Arm, zone has exit/entry
(OP) delay
[3][0][9] I+EN
FOLLOW
Stay arm, zone will be
bypass automatically;
Arm, zone has entry
follower
[3][1][0] I+INSTANT
Stay arm, zone will be
bypass automatically;
Arm, it is Instant
zone
[3][1][1] UO
Trigger
No alarm and code report,
but trigger the
programmed output
[3][1][2] Day
When the system is
triggered, It will alarm at
the armed state and
report trouble at the
disarmed state
[3][1][3] 24
Hours
The zone will be triggered,
whatever the system is
armed or disarmed
[3][1][4] Fire
Armed, It will alarm when
the short the port;
Disarmed, it will report
trouble when open the port
[3][1][5] Panic
There will be panic alarm
when it is triggered
[3][1][6] Medical
zone
There will be medical
emergency alarm when it
is triggered
[3][1][7] Key
Switch
Zones can be used as
switch
[3][1][8] EXIT
TERM
Usually avoid the wrong
alarm for exit form room
which user exit after end of
extend time close
[3][1][9]
LATCH KSW
If want to arm or disarm to