Parameters:
<Coupling>
AC | DC
AC
The DC voltage component is disconnected from the modulation
signal.
DC
The modulation signal is not changed.
*RST:
AC
Example:
PM:EXT:COUP AC
selects the coupling mode AC for external phase modulation.
Usage:
SCPI confirmed
[:SOURce<hw>]:PM:EXTernal:DEViation
<Deviation>
The command sets the modulation deviation in case of external phase modulation in
RAD. The maximal deviation depends on the RF frequency set and the selected modu-
lation mode (see data sheet).
Parameters:
<Deviation>
float
Range:
0 to 20
Increment: See data sheet
Default unit: RAD
Example:
PM 5
sets the PM modulation deviation for external phase modulation
of 5 RAD.
Usage:
SCPI confirmed
[:SOURce<hw>]:PM:SENSitivity?
The command queries the input sensitivity of the EXT MOD input in RAD/V. The com-
mand is only effective if the external modulation source is selected (
SOUR:PM:SOUR
EXT
). The returned value depends on the modulation deviation setting
(
SOUR:PM:DEViation
). This value is assigned to the voltage value for full modulation
of the input.
Return values:
<Sensitivity>
float
Example:
PM:DEV 1
sets a modulation deviation of 1RAD.
PM:SENS?
queries the input sensitivity at the EXT MOD input.
Response: 1
since the voltage value for full modulation is 1V, the resulting sen-
sitivity is precisely 1RAD/V.