Instrument Function
R&S
®
SMC100A
162
Operating Manual 1411.4060.32 ─ 04
5.5.4.1
Pulse Generator Settings
The dialog provides the settings for the pulse characteristics and trigger mode.
Video Sync Signal State - Pulse Generator
Switches on/off the output of the video/sync signal at the PULSE VIDEO connector. The
signal output and the pulse generator are automatically switched on with activation of
pulse modulation if pulse generator is selected as modulation source. The signal output
can be switched off subsequently.
Pulse modulation of the RF carrier is activated in the "Pulse modulation" menu of the
"Modulation" block.
SCPI command:
Pulse Mode - Pulse Generator
Sets the mode of the pulse generator.
"Single"
A single pulse is generated in one pulse period.
"Double"
Two pulses are generated in one pulse period. Additional settings for
the double pulse are available in the menu.
SCPI command:
Pulse Period - Pulse Generator
Sets the period of the generated pulse. The period determines the repetition frequency
of the internal signal.
SCPI command:
Pulse Width - Pulse Generator
Sets the width of the generated pulse. The width determines the pulse length. The pulse
width must be at least 20 ns less than the set pulse period.
SCPI command:
Pulse Delay - Pulse Generator
(External trigger only)
LF Generator and LF Output - Mod Gen
Содержание SMC100A
Страница 1: ...R S SMC100A Signal Generator Operating Manual Operating Manual XÊP 1411 4060 32 04 Test Measurement ...
Страница 67: ......
Страница 339: ......
Страница 341: ......