![Rohde & Schwarz FSQ series Скачать руководство пользователя страница 128](http://html.mh-extra.com/html/rohde-and-schwarz/fsq-series/fsq-series_quick-start-manual_1477838128.webp)
R&S FSQ
Measuring Signal Spectra with Multiple Signals
5.18
Quick Start Guide 1313.9652.62 - 02
Fig. 5-8
Measurement of two RF equally-sized sinusoidal signals with a resolution
bandwidth (1 kHz) which is clearly smaller than their frequency spacing.
6. Activate the FFT bandwidths.
➢
Using the
FILTER TYPE
softkey in the selection list, set the filter type to
FFT
. IF filtering
is now performed using the FFT algorithm. The sweep time decreases significantly from
600 ms to 25 ms (a factor of 24). The display update rate also increases by almost the
same ratio.
Fig. 5-9
Measurement with FFT filters gives a considerably shorter sweep time and a
higher refresh rate.