![Rohde & Schwarz CMW500 Series Скачать руководство пользователя страница 255](http://html1.mh-extra.com/html/rohde-and-schwarz/cmw500-series/cmw500-series_user-manual_1477718255.webp)
Command Reference
R&S
®
CMW500
255
User Manual 1173.9463.02 ─ 02
Firmware/Software:
V1.0.10.1
2.0.10: Query parameters <OptionType> and <Validity> added
SYSTem:BASE:RELiability?
Returns the common reliability indicator.
Return values:
<Value>
See
"Common Reliability Indicator"
Usage:
Query only
Firmware/Software:
V2.0.10
SYSTem:CONNector:TRANslation?
<Connector>
Queries the relation between absolute and virtual connector names. You can query this
relation for either an absolute or a virtual name. As a result both absolute and virtual name
are returned. For background information see
chapter 6.4.4.2, "RF Connector Values"
Query parameters:
<Connector>
RF1O | RF1C | RF2C | RF3O | RF3C | RF4C | RFAO | RFAC |
RFBC
RF1C, RF2C, RF3C, RF4C, RF1O, RF3O:
RF 1 COM to RF 4 COM and RF 1/3 OUT front panel connectors
RFAC, RFBC, RFAO:
Virtual names for the RF COM and RF OUT connectors
Return values:
<VirtualConnector>
RFAO | RFAC | RFBC
<AbsoluteConnector> RF1O | RF1C | RF2C | RF3O | RF3C | RF4C
Example:
SYSTem:CONNector:TRANslation? RFAC
Returns e.g.
RFAC, RF1C
SYSTem:CONNector:TRANslation? RF2C
Returns e.g.
RFBC, RF2C
Usage:
Query only
Firmware/Software:
V2.0.10
SYSTem:DATE
<Year>, <Month>, <Day>
Sets the date of the internal calendar.
Parameters:
<Year>
Year, to be entered as a four-digit number (including the century
and millenium information)
<Month>
Month, 1 (for January) to 12 (for December)
Instrument-Control Commands