User Manual 1173.9463.02 ─ 02
Remote and manual control
The RPM principles described in this section are valid in remote as well as in manual
control. In remote control, running different tasks in parallel enhances the speed and
performance of the tester. In manual control, it allows you to monitor different measure-
ments simultaneously and compare the results.
6.4.5.1
Basic RPM Principles
The principles of R&S CMW500 Resource and Path Management can be summarized
very briefly:
●
Non-conflicting tasks can run in parallel without restriction.
●
A new measurement or generator that is in conflict with a running task replaces the
running task.
Exception:
Measurements cannot replace generator or signaling appli-
cations. A new, conflicting measurement is blocked until a running generator or sig-
naling application is switched off by other means.
●
Generator and signaling applications are released immediately, measurements are
released after the current measurement cycle.
According to the last rule, conflicting measurements are queued, see
. A new measurement is started only after all previous measurements have
been terminated in a regular way.
The RPM principles can be visualized as follows:
Two measurements in conflict, second measurement queued
Generator and measurement in conflict
Signaling applications behave like generators and must be turned off explicitly.