![Rohde & Schwarz CMW500 Series Скачать руководство пользователя страница 241](http://html1.mh-extra.com/html/rohde-and-schwarz/cmw500-series/cmw500-series_user-manual_1477718241.webp)
Command Reference
R&S
®
CMW500
241
User Manual 1173.9463.02 ─ 02
Suffix:
<n>
.
8 to 12
Number of the bit
Return values:
<BitValue>
0 | 1
Example:
STAT:QUES:BIT9:COND?
Query bit no. 9 of the CONDition part of the STATus:QUEStiona-
ble register.
Usage:
Query only
Firmware/Software:
V1.0.4.11
STATus:QUEStionable:BIT<n>:ENABle
<BitValue>
STATus:QUEStionable:BIT<n>:NTRansition
<BitValue>
STATus:QUEStionable:BIT<n>:PTRansition
<BitValue>
Sets bit no. <n> of the ENABle, NTRansition or PTRansition part of the STATus:QUES-
tionable register, see also
Structure of an SCPI Status Register
. To set the entire parts
and
.
Suffix:
<n>
.
8 to 12
Number of the bit
Parameters:
<BitValue>
0 | 1
Example:
STAT:QUES:OPER:BIT9:ENAB 1
Set bit no. 9 of the ENABle part of the STATus:QUEStionable reg-
ister.
Firmware/Software:
V1.0.4.11
7.3.8 SYSTem Commands
The SYSTem subsystem contains functions that are not related to instrument perform-
ance. Most of the commands are SCPI-confirmed.
Reference Frequency and System Synchronization Settings
...............................250
...........................................................................................252
Miscellaneous Instrument Settings
.......................................................................253
Instrument-Control Commands