![Rohde & Schwarz CMW500 Series Скачать руководство пользователя страница 158](http://html1.mh-extra.com/html/rohde-and-schwarz/cmw500-series/cmw500-series_user-manual_1477718158.webp)
Remote Control
R&S
®
CMW500
158
User Manual 1173.9463.02 ─ 02
sub-instrument, not per instrument. That means e.g. that within sub-instrument 1 the
value
TX1
refers to another physical TX module than within sub-instrument 2.
The following table lists the supported parameter values and used *RST values for selec-
tion of RF connectors and TX/RX boards.
Sub-Instrument 1
Sub-Instrument 2
Input connector
RF1C | RFAC
RF2C | RFAC
Output connector
RF1C | RF1O | RFAC |
RFAO
RF2C | RFAC
Mapping
RFAC, RFAO
RF1C, RF1O
RF2C, n/a
TX module
TX1
TX1
RX module
RX1
RX1
*RST connectors
RF1C
RF2C
*RST TX/RX
TX1, RX1
TX1, RX1
6.4.4.9
Four RF Output Paths, Two Frontends, One Sub-Instrument
This section applies to an instrument with four RF output paths, two RF input paths and
two advanced frontends. It provides four instances for generator applications and two
instances for measurement applications. All resources are grouped in one sub-instru-
ment.
All firmware application instances can access both frontends. The following table lists the
supported parameter values and used *RST values for selection of RF connectors and
TX/RX boards.
Instance 1
Instance 2
Instance 3
Instance 4
Input connector
RF1C | RF2C | RF3C | RF4C | RFAC | RFBC
Output connector
RF1C | RF1O | RF2C | RF3C | RF3O | RF4C | RFAC | RFAO
| RFBC
Mapping
RFAC, RFAO, RFBC
RF1C, RF1O, RF2C
TX module
TX1, TX3
(for RF1/RF2 connectors only)
TX2, TX4
(for RF3/RF4 connectors only)
RX module
RX1
(for RF1/RF2 connectors only)
RX2
(for RF3/RF4 connectors only)
*RST connectors
RF1C
RF3C
RF2C
RF4C
*RST TX/RX
TX1, RX1
TX2, RX2
TX3, n/a
TX4, n/a
Control of the Instrument