User Manual 1173.9463.02 ─ 02
●
ROUTe:<Application>:SIGNaling<i>:SCENario:SCELl
ROUTe commands changed in V2.0.10
Routing commands of the type
ROUTe:<Application>:<Instance>:RFSettings:CONNector
are no longer
supported for software versions
≥
V2.0.10. The old routing commands select only an RF
connector but no RX/TX module and must no longer be used.
Furthermore the selection of connectors RF 3 COM, RF 3 OUT and RF 4 COM has
changed in software version V2.0.10. From V2.0.10 on these connectors are identified
via their correct names
RF3C
,
RF3O
and
RF4C
or via virtual names. The old values
RF1C
,
RF1O
and
RF2C
always identify the connectors RF 1 COM, RF 1 OUT and RF 2
COM.
For command script conversion see GPRF examples below.
Example: Script conversion for two instances in one sub-instrument
Use RF 1 OUT for instance 1 and RF 3 OUT for instance 2 of the GPRF generator.
●
Old commands (< V2.0.10):
ROUTe:GPRF:GEN1:RFSettings:CONNector RF1O
ROUTe:GPRF:GEN2:RFSettings:CONNector RF1O
●
New commands (≥ V2.0.10):
ROUTe:GPRF:GEN1:SCENario:SALone RF1O, TX1
ROUTe:GPRF:GEN2:SCENario:SALone RF3O, TX2
Example: Script conversion for two sub-instruments with one instance each
Use RF 2 COM for sub-instrument 1 and RF 4 COM for sub-instrument 2 to run a GPRF
measurement.
●
Old command to be sent to both sub-instruments:
ROUTe:GPRF:MEAS:RFSettings:CONNector RF2C
or
ROUTe:GPRF:MEAS:SCENario:SALone RF2C, RX1
●
New command to be sent to both sub-instruments (virtual connector name):
ROUTe:GPRF:MEAS:SCENario:SALone RFBC, RX1
●
Or new commands with individual connector names (same effect):
sub-instrument 1:
ROUTe:GPRF:MEAS:SCENario:SALone RF2C, RX1
sub-instrument 2:
ROUTe:GPRF:MEAS:SCENario:SALone RF4C, RX1
6.4.4.1
Supported Signal Paths
The signal path configuration is straightforward if the instrument provides only one RF
path (one RX/TX module). If the instrument provides several RF paths, the supported
paths depend on the installed hardware and differ for instruments split into two sub-
instruments and instruments assigning all resources to one sub-instrument.
Thus also the values supported for RF path configuration vary depending on your instru-
ment setup. To understand the signal paths supported at your instrument you may consult
the
or the RF path settings at the GUI. Both provide only supported
values for selection.
Control of the Instrument