Page 37
CABINET HEATER
4.5
Gas Supply
General
The installation must comply with local laws and regulations, and the complete installation including the meter, where
fitted, must be purged and tested for soundness.
The gas supply must be adequately sized to carry a sufficient quantity of gas at the specified pressure at the heater
inlet whilst firing (see data tables in section 2).
The gas supply must be sized to supply the correct amount of gas to the heater under all load conditions.
It will generally be required to use installation pipes of a larger diameter than the heater inlet connection.
The supply should terminate at each heater with a service cock and a union so as to facilitate the removal of the gas
train for servicing (see Fig 3.1).
Natural Gas
The gas meter and service must be checked by the local gas supply undertaking to ensure that it is adequate to deal
with the total connected load of the completed installation.
Each heater must be provided with gas having the inlet pressure controlled at 20 mbar (17mbar - 25mbar)
L.P.G.
For L.P.G applications each heater must be provided with gas having an inlet pressure controlled at 37mbar (25mbar
- 45mbar) for propane (G31).
Содержание Combat HF 30 v4
Страница 2: ......
Страница 47: ...Page 45 CABINET HEATER Section 6 Wiring Diagrams Fig 6 1 As Wired Diagram for Models 015 to 030 Floor Standing ...
Страница 48: ...Page 46 CABINET HEATER Fig 6 2 As Wired Diagram for Models 015 to 030 Horizontal Mounting ...
Страница 49: ...Page 47 CABINET HEATER Fig 6 3 As Wired Diagram for Models 040 and 050 Floor Standing ...
Страница 50: ...Page 48 CABINET HEATER Fig 6 4 As Wired Diagram for Models 040 050 Horizontal Mounting ...
Страница 51: ...Page 49 CABINET HEATER Fig 6 5 As Wired Diagram for Models 060 to 0100 Floor Standing ...
Страница 52: ...Page 50 CABINET HEATER Fig 6 6 As Wired Diagram for Models 060 to 0100 Horizontal Mounting ...
Страница 55: ...Page 55 CABINET HEATER Fig 6 12 Wiring Diagram for High Flow Models HF40 v3 HF50 v2 HF50 v3 and HF50 v4 ...