CABINET HEATER
T
he gas fired versions of these appliances have been tested and certified
as complying with the essential requirements of the Gas Appliance Directive, the
Electromagnetic Compatibility Directive, The Low Voltage directive and the Machinery Directive
for use on natural gas and L.P.G. Propane when installed, commissioned and maintained in
accordance with these instructions
The gas fired heaters are category II
2H 3P
for natural gas or propane gas and are type B
23
for
a natural draught flue.
These instructions refer to gas appliances designed to operate in the following countries:
United kingdom (GB), Ireland (IE), Italy (IT) and Spain (ES)
The oil fired versions may also operate in these countries in accordance with local rules and
laws.
The oil fired versions are constructed to the same Basic design criteria to burn fuel oil as
specified below but there is no similar testing available for these products at the time of
writing these instructions.
However the safe operation of the heaters depends on the proper installation, commissioning
and maintenance of the appliances in accordance with these instructions .
The fuel specified for oil fired burners is:
Class D fuel oil to BS 2869
Which is similar to Gas oil with a maximum viscosity at 20° C of 1.5° E
These appliances must be installed in accordance with the rules in force, and used only in a
sufficiently ventilated space, as specified in these instructions and local regulations.
Before installation, check that the local distribution conditions of the fuel, the quality of the
fuel and the appliance adjustment are compatible.
These instructions cover the installation setting and operation of all variations of the COMBAT®
range of cabinet heaters. The burner manufacturers instructions are also provided to give
detailed instructions on the operation of the burner. The settings for use of the burner with
the air heater are shown in these instructions or the relevant supplement which is issued with
the appliance to cover specific features available for various options.
It is important that all of the relevant information is used when installing, setting or operating
this equipment
© 2003
All rights reserved. No part of this work covered by the copyrights herein may be
reproduced or copied in any form or by any means - graphic, electronic, or mechanical,
including photocopying, recording, taping, or information storage and retrieval systems -
without written permission of Roberts-Gordon.
Содержание Combat HF 30 v4
Страница 2: ......
Страница 47: ...Page 45 CABINET HEATER Section 6 Wiring Diagrams Fig 6 1 As Wired Diagram for Models 015 to 030 Floor Standing ...
Страница 48: ...Page 46 CABINET HEATER Fig 6 2 As Wired Diagram for Models 015 to 030 Horizontal Mounting ...
Страница 49: ...Page 47 CABINET HEATER Fig 6 3 As Wired Diagram for Models 040 and 050 Floor Standing ...
Страница 50: ...Page 48 CABINET HEATER Fig 6 4 As Wired Diagram for Models 040 050 Horizontal Mounting ...
Страница 51: ...Page 49 CABINET HEATER Fig 6 5 As Wired Diagram for Models 060 to 0100 Floor Standing ...
Страница 52: ...Page 50 CABINET HEATER Fig 6 6 As Wired Diagram for Models 060 to 0100 Horizontal Mounting ...
Страница 55: ...Page 55 CABINET HEATER Fig 6 12 Wiring Diagram for High Flow Models HF40 v3 HF50 v2 HF50 v3 and HF50 v4 ...