DigitalSpot 3000 DT
25
Reset Focus/Shutter system
--- This function resets a focus module.
Reset All systems
--- This function enables you to return all fixture´s effects to their standard positions.
15.9 Service menu
Use this menu to read useful information about the fixture.
Power On Time
- Select this submenu to read the number of operation hours of the fixture.
Total Hours
- The function shows the total number of the operation hours since
the DigitalSpot 3000 has been fabricated.
Resetable Hours
- The function shows the number of the operation hours that
the DigitalSpot 3000 has been powered on since the counter was last reset. In order
to reset this counter to 0, press [ENTER] twice.
Lamp On Time
- Select this submenu to read the number of the operation hours with the projector lamp on.
Total Hours
- The function shows the total number of the operation hours with the lamp
on since the DigitalSpot 3000 has been fabricated.
Resetable Hours
- The function shows the number of the operation hours with the
lamp on that the DigitalSpot 3000 has been powered on since the counter was last reset.
In order to reset this counter to 0, press [ENTER] twice.
Lamp Strikes
- Select this submenu to read the total number of the projector lamp strikes.
Total Hours
- The function shows the total number of the lamp strikes since
the DigitalSpot 3000 has been fabricated.
Resetable Hours
- The function shows the number of the lamp strikes since
the counter was last reset. In order to reset this counter to 0, press [ENTER] twice.
Fixture Temperatures
--- Select this submenu to read the temperatures of the projector:
Current
- Select this function to read the current temperatures of the fixture interior .
Maximum nonresetable
-The function shows the max. temperatures of the fixture interior
since the DigitalSpot 3000 DT has been fabricated.
Maximum resetable
- The function shows the maximum temperatures of the fixture interior
since the respective counter was last reset. In order to reset desired counter to 0,
press [ENTER] twice.
Measuring points of temperatures:
Pan /Tilt Board. [°C] ...............temperature on the PCB in the fixture base
Led Panel Board [°C]................temperature in the LED module
Air Filters
--- Regular cleaning of the air filters is very important for the DigitalSpot 3000 DT life and performance.
Buildup of dust, dirt and fog fluid residues reduces the fixture´s light output and cooling ability. The two items of
menu help you to keep cleaning period of the air filters.
Time To Cleanup Filters
- The option allows you to read the time which remains to
cleaning air filters. Expired time period is signalized by a negative mark at the time value and
a warning icon (triangle) on the display with the following message:
"Please , Clean Up Airs Filters."
Clean the filters and reset this menu item (by pressing the "Enter" button twice while
this menu is highlighted)
Set Cleanup Timer
- Cleaning schedule for the fixture depends on the operating
environment. It is therefore impossible to specify accurate cleaning interval. This function
allows you to change the cleaning interval of the air filters. This "reminder" value is
50 hours and it is set as default. Inspect fixture within its 50 hours of operation to see
whether cleaning is necessary. If cleaning is required, clean all air filters and change
the value in this menu on acceptable level. Min. level is 10 hours, max. is 300 hours.