MALFUNCTIONS
85
LED next to START button at
bottom right of the Riomote
control flashes after a short period
of operation.
Battery not charged or defective.
•
Fully charge the battery or
•
Replace battery.
Check whether charging process is
working correctly.
•
Check battery contact
terminals or
•
Clean battery contact
terminals.
Indications on Riomote control are
good, but functions are not
performed.
Emergency stop pressed.
Turn button left or right to unlock
emergency stop.
Receiver has no power.
1.
Check fuse.
2.
Replace any blown fuse.
No connection to receiver.
Check all indicator lights for all
functions.
Command via Riomote control not
performed.
Open in electrical circuit.
1.
Check all plug connections.
2.
Push plugs in or
3.
Connect detached plugs.
Check all indicator lights for all
functions.
Receiver defective.
Contact Rioned.
Fault
Cause
Solution