MALFUNCTIONS
82
Fault
Cause
Solution
High pressure pump does not
produce required pressure.
Water tank empty.
Fill water tank.
Supply valve to water filter closed.
Open supply valve.
Water filter restricted.
Stop machine. Clean water filter.
Air in high pressure pump.
1.
Let the machine run several
minutes with the high
pressure valve open.
2.
If the fault is not cleared,
contact Rioned.
Suction valves of high pressure
pump seized.
1.
Carefully free the valves.
2.
Remove any lime scale build-
up.
Suction valves of high pressure
pump worn.
Contact Rioned.
High pressure pump does not
produce required pressure.
Water tank empty.
Fill water tank.
Supply valve to water filter closed.
Open supply valve.
Water filter restricted.
Stop machine. Clean water filter.