55
Menu Operations and Setting Items
<Synchronization> menu
Contains settings for operating two connected DA-21 units as a synchronized
system.
For additional information on DA-21 synchronized operation, also refer to
page 91.
Master / Slave
Assign unit to master or slave operation
After connecting two DA-21 units, this setting determines whether the
respective DA-21 unit operates as master or as slave.
OFF
No synchronized operation.
Master Select this setting on the DA-21 to be used as master.
Slave Select this setting on the DA-21 to be used as slave.
Synchronize
Synchronize connected DA-21 units
Use the dedicated cable to connect the two DA-21 units to be used as
master and slave. Select this item on both units and press the [ENT] key.
The execution choice screen appears. Then press the [ENT] key on both
unit simultaneously. Two connected DA-21 units synchronize.
Important
Establish the same settings on both DA-21 units
(<Rec.Parameters> menu items). If settings are
different, synchronized operation is not possible.
Also, when the settings are changed after the
synchronization, it is necessary to synchronize
again.
Check the synchronization information on the
display (page 18) after operation of the syn-
chronization.