5.9
SET.PTS: Setpoints Menu
This section is used to set all of the operational logic of the setpoint system, as well as provide for the entry
of secure setpoint target and inflight values.
Items
Name
Description
General
GEN
General setpoint settings
Jog on time
JOG.ON
Job on time in milliseconds. Only used for pulse setpoint timing.
Jog off time
JOG.OFF
Job off time in milliseconds. Only used for pulse setpoint timing.
Jog set
JOG.SET
Number of jogs in a set. Only used for pulse setpoint timing.
Maximum sets
MAX.SET
Maximum number of jog sets. Only used for pulse setpoint timing.
Feeder
FEEDER
Feeder type for weigh in and weigh out setpoints. Options are:
MULT.: Outputs will run in parallel (default)
SINGLE: Outputs will run serially
Delay check
DLY.CHK
Delay time in milliseconds after weigh in or weigh out setpoint
becomes active before weight is checked again.
Setpoint 1
Setpoint 2
Setpoint 3
Setpoint 4
Setpoint 5
Setpoint 6
Setpoint 7
Setpoint 8
SET.PT.1
SET.PT.2
SET.PT.3
SET.PT.4
SET.PT.5
SET.PT.6
SET.PT.7
SET.PT.8
Setpoint settings
Setpoint type
TYPE
Set setpoint type. Options are:
OFF: Disabled (default)
ON: Always active
OVER: Weight over setpoint
UNDER: Weight under setpoint
COZ: Centre of zero status
ZERO: Zero band status
NET: Gross/net status
MOTION: Motion status
ERROR: Error status
BUZZER: Buzzer status
W. OUT: Weigh out setpoint
W. IN: Weigh in setpoint
Target
TARGET
Setpoint target. Only used for weight setpoints.
Hysteresis
HYS
Setpoint hysteresis. Only used for weight setpoints.
Inflight
FLIGHT
Setpoint inflight. Only used for weight setpoints.
Lock
LOCK
Disable operator access (via operator menus). Options are:
OFF(def): menu access available
ON: menu access locked
Source
SOURCE
Select source for weight setpoints. Options are:
GROSS(def): use gross weight.
NET: use net weight.
Output logic
LOGIC
Output logic. Options are:
HIGH(def): output is high when setpoint is active.
LOW: output is low when setpoint is active.
31
C500-600-2.0.3
Содержание C500 series
Страница 1: ...C500 Series Digital Indicator Reference Manual ...
Страница 54: ...8 3 Custom Format Tokens 8 3 1 Formatting 49 C500 600 2 0 3 ...
Страница 56: ...230 Send time in format hh mm ss 231 Send Date in format dd mm yyyy 51 C500 600 2 0 3 ...
Страница 120: ...Select C500 and click create Enter the module name description and IP address then click change 115 C500 600 2 0 3 ...
Страница 123: ...118 C500 600 2 0 3 ...
Страница 182: ...177 C500 600 2 0 3 ...