Operation of the
external inputs
Remote Key 1
Remote Key 2
Remote Key 3
Remote Key 4
Remote Key 5
Remote Key 6
Remote Key 7
Remote Key 8
IN.FN
IN.FN.1
IN.FN.2
IN.FN.3
IN.FN.4
IN.FN.5
IN.FN.6
IN.FN.7
IN.FN.8
Set the function of the remote inputs (see Section 17). Options
are:
NONE
ZERO
TARE
GROSS
BLANK
LOCK
SHW.TOT
CLR.TOT
UNDO
SINGL.1
SINGL.2
M.HOLD
P.HOLD
L.HOLD
TXT.PRN
SINGL.3
SINGL.4
UNITS
UNUSED
UNUSED
SP.RST.A
SP.RST.B
Defaults: All inputs = NONE
Buzzer Enable
BUZZER
Enables and disables the buzzer operation. Options are:
OFF
ON (default)
Display Brightness
BRIGHT
Set the display brightness (0..100%). Default: 100%
Secondary Units
UNIT.2
Set the secondary units. Options are:
OFF (default)
G
KG
LB
OZ
CUSTOM
Tertiary Units
UNIT.3
Set the tertiary units. Options are:
OFF (default)
G
KG
LB
OZ
Custom Unit Factor
FACTOR
Set
the
conversion
factor
for
custom
secondary
units
(0.001..999.999) Default is 1.000.
LB-OZ display
LB.OZ
Display oz weights as lb-oz where possible. Options are:
OFF (default)
ON
⊕
= Change only possible in FULL Setup
29
C500-600-2.0.3
Содержание C500 series
Страница 1: ...C500 Series Digital Indicator Reference Manual ...
Страница 54: ...8 3 Custom Format Tokens 8 3 1 Formatting 49 C500 600 2 0 3 ...
Страница 56: ...230 Send time in format hh mm ss 231 Send Date in format dd mm yyyy 51 C500 600 2 0 3 ...
Страница 120: ...Select C500 and click create Enter the module name description and IP address then click change 115 C500 600 2 0 3 ...
Страница 123: ...118 C500 600 2 0 3 ...
Страница 182: ...177 C500 600 2 0 3 ...