Parameter
Description
Range
Default
1
Setpoint number
1 .. 8
-
2
Type
0 = OFF
1 = ON
2 = OVER
3 = UNDER
4 = COZ
5 = ZERO
6 = NET
7 = MOTION
8 = ERROR
9 = BUZZER
10 = W. OUT
11 = W. IN
0
3
Data source
1 = Gross
2 = Net
1
4
Switching direction. Legacy do not use, always returns 1.
Use type over or under instead.
1 = Over
2 = Under
1
5
Target Weight
-999999 .. 999999
0
6
Inflight Weight
0 .. 999999
0
7
Hysteresis Weight
0 .. 999999
0
8
Logic
1 = Active High
2 = Active Low
1
9
Lock
0 = Off
1 = On
0
10
Alarm
0 = Off
1 = Single
2 = Dual
3 = Continuous
4 = Flashing
0
11
Timing
0 = LEVEL
1 = EDGE
2 = LATCH
3 = PULSE
0
12
Reset
0 = NONE
1 = SP.RST.A
2 = SP.RST.B
0
Example
Command
Answer
Description
S01;
Select unit 1
LIV?1;
1,0,1,1,0,0,0,1,0,0,0,0 CRLF
Query setpoint 1 parameters
LIV1,2,1,1,1000,100,10,1,0,0,0,0;
0 CRLF
Change setpoint 1 to: over,
gross, over switching, tar-
get = 1000, inflight = 100,
hysteresis = 10, active high
logic, no lock, alarm off, level
timing, no reset.
TDD1;
0 CRLF
Save setting
21.3.30
LIW: General Setpoints
Set the general parameters for the setpoints.
General
141
C500-600-2.0.3
Содержание C500 series
Страница 1: ...C500 Series Digital Indicator Reference Manual ...
Страница 54: ...8 3 Custom Format Tokens 8 3 1 Formatting 49 C500 600 2 0 3 ...
Страница 56: ...230 Send time in format hh mm ss 231 Send Date in format dd mm yyyy 51 C500 600 2 0 3 ...
Страница 120: ...Select C500 and click create Enter the module name description and IP address then click change 115 C500 600 2 0 3 ...
Страница 123: ...118 C500 600 2 0 3 ...
Страница 182: ...177 C500 600 2 0 3 ...