EM-1010 computerized Embroidery Machine Operation Manual V2.0
2
Please don’t pile up debris around the control cabinet. During using process, clean the
surface of control cabinet and dust on filter regularly to ensure good ventilation of system and
be conductive for heat radiation.
Without authorization of the company, please don’t modify the products. Otherwise, the
company undertakes no liability for the caused results!
Warning
When it is necessary to open the case cover, it can only permit to touch the parts in the
electrical cabinet under the guidance of professional personnel after 5 minutes.
Prohibition
When the machine is in operation, it is prohibit touching any moving part or opening
control equipment. Otherwise, it may cause personnel injury or cause abnormal operation of
machine.
It is prohibit operating electrical equipments in working environment with moisture, dust,
corrosive gases and flammable and explosive gases. Otherwise, it may cause electric shock or
fire.
1.3 Working Environment
Good ventilation, healthy environment, less dust;
Working space temperature: 5-40 °;
Working Space Relative Humidity: 30% -90% non-condensing
1.4 System Power Supply and Earthing
The electric control system can use the following power:
Single phase AC100-220V/50-60HZ
According to different machine configuration, power consumption is between 0.1-0.4KW.
To prevent electrical equipment from causing electric shock or fire accidents due to
electric leakage, over-current, insulation and other causes, please earth the electric
control reliably.