Address
Function
Unit
Remarks
6805E4
Bit 0 – OHS (on hook speed)
0: OHS=0
1: OHS=1
Bit 1 – SQ (spark quench)
0: SQ=00
1: SQ=11
Bit 2 – RZ (call signal Impedance)
0: RZ=0 (high)
1: RZ=1 (low)
Bit 3 – RT (call signal detection level)
0: RT=0 (low)
1: RT=1 (high)
Bit 4 – ILIM (DC limitation)
0: ILIM=0 (CTR 21)
1: ILIM=1 (other than CTR 21)
Bit 5 –FILTER
0: FILTER=0 (around 5Hz)
1: FILTER=1 (around 200Hz)
Bits 6 to 7 – Calibration in off hook state
Bit 6:0, Bit 7: 0 = off hook to ACAL:128 ms, off hook to MCAL: 1000 ms
Bit 6:1, Bit 7: 0 = off hook to ACAL:128 ms, off hook to MCAL: 500 ms
Bit 6:0, Bit 7: 1 = off hook to ACAL:128 ms (no MCAL)
Bit 6:1, Bit 7: 1 = off hook to ACAL:8 ms (no MCAL)
6805E5
Bits 0 to 6 – Not used
Bits 7 – Energy saving for DSP, COMBLK, SiDAA
0: Does not save energy
1: Saves energy
NOTES
1. If a setting is not required, store FF in the address.
2. Italy and Belgium only
RAM address 68055E: the lower four bits have the following meaning.
NCU Parameters
173
Содержание Type M12
Страница 1: ...Fax Option Type M12 Machine Code D3A5 Field Service Manual July 2014 Subject to change...
Страница 2: ......
Страница 10: ...8...
Страница 22: ...2 Remove the controller cover A x 4 3 Remove the controller rear cover A x 5 1 Installation 20...
Страница 28: ...Fax Unit Options Memory Unit Type M12 64MB 1 Remove the controller box cover x 4 1 Installation 26...
Страница 50: ...2 Replacement and Adjustment 48...
Страница 84: ...3 Troubleshooting 82...
Страница 218: ...5 Detailed Section Descriptions 216...
Страница 226: ...MEMO 224 EN...