G3 Switch 0C (SP No. 1-105-013)
No
Function
Comments
0-1
Not used
Do not change these settings.
4-5
Select detection of DTMF/DP
detection when using remote switch.
00: DTMF+PSTN (Simultaneous
detection)
01: DTMF
10: DP (10 PPPS)
11: DP (20 PPS)
This setting determines how to detect the signals from
the handset when remote switch is active.
G3 Switch 0D Not used (do not change the settings).
G3 Switch 0E (SP No. 1-105-015)
No
Function
Comments
0-7
Set CNG send time interval
Some machines on the receiving side may not be able to automatically switch the 3-second
CNG interval.
High order bit
3000-2250ms: 3000-50xNms
3000 – 50 x Nms 0F (3000 ms) <= N <= FF (2250 ms)
Low order bit
00-0E(3000-3700ms: 3000+50xNms
3000 – 50 x Nms 0F (3000 ms) <= N <= 0F (3700
ms)
G3 Switch 0F (SP No. 1-105-016)
No
Function
Comments
0
Alarm when an error occurred in
Phase C or later
0: Disabled
1: Enabled
If the customer wants to hear an alarm after each error
communication, change this bit to "1".
Bit Switches - 4
141
Содержание Type M12
Страница 1: ...Fax Option Type M12 Machine Code D3A5 Field Service Manual July 2014 Subject to change...
Страница 2: ......
Страница 10: ...8...
Страница 22: ...2 Remove the controller cover A x 4 3 Remove the controller rear cover A x 5 1 Installation 20...
Страница 28: ...Fax Unit Options Memory Unit Type M12 64MB 1 Remove the controller box cover x 4 1 Installation 26...
Страница 50: ...2 Replacement and Adjustment 48...
Страница 84: ...3 Troubleshooting 82...
Страница 218: ...5 Detailed Section Descriptions 216...
Страница 226: ...MEMO 224 EN...