4-7
Not used
Do not change the settings.
Communication Switch 06 - Not used (do not change the settings)
Communication Switch 07 - Not used (do not change the settings)
Communication Switch 08 - Not used (do not change the settings)
Communication Switch 09 (SP No. 1-104-009)
No
Function
Comments
0-7
Minimum interval between automatic
dialing attempts
This value is the minimum time that the machine
waits before it dials the next destination.
Communication Switch 0A (SP No. 1-104-011)
No
Function
Comments
0
Point of resumption of memory
transmission upon redialing
0: From the error page
1: From page 1
0: The transmission begins from the page where
transmission failed the previous time.
1: Transmission begins from the first page, using
normal memory transmission.
1-7
Not used
Do not change these settings.
Communication Switch 0B (SP No. 1-104-012)
No
Function
Comments
0-3
Not used
Do not change these settings.
4
Printout of the message when acting
as a Transfer Station
0: Disabled, 1: Enabled
When the machine is acting as a Transfer Station, this
bit determines whether the machine prints the fax
message coming in from the Requesting Terminal.
5-7
Not used
Do not change the settings.
Communication Switch 0C - Not used (do not change the settings)
Communication Switch 0D (SP No. 1-104-014)
Bit Switches - 3
127
Содержание Type M12
Страница 1: ...Fax Option Type M12 Machine Code D3A5 Field Service Manual July 2014 Subject to change...
Страница 2: ......
Страница 10: ...8...
Страница 22: ...2 Remove the controller cover A x 4 3 Remove the controller rear cover A x 5 1 Installation 20...
Страница 28: ...Fax Unit Options Memory Unit Type M12 64MB 1 Remove the controller box cover x 4 1 Installation 26...
Страница 50: ...2 Replacement and Adjustment 48...
Страница 84: ...3 Troubleshooting 82...
Страница 218: ...5 Detailed Section Descriptions 216...
Страница 226: ...MEMO 224 EN...