No
Function
Comments
0-7
The available memory threshold,
below which ringing detection (and
therefore reception into memory) is
disabled
00 to FF (Hex), unit = 4 kbytes
(e.g., 06(H) = 24 kbytes)
One page is about 24 kbytes.
The machine refers to this setting before each fax
reception. If the amount of remaining memory is below
this threshold, the machine cannot receive any fax
messages.
If this setting is kept at 0, the machine will detect ringing
signals and go into receive mode even if there is no
memory available. This will result in communication
failure.
Communication Switch 0E (SP No. 1-104-015)
No
Function
Comments
0-7
Minimum interval between
automatic dialing attempts
06 to FF (Hex), unit = 2 s
(e.g., 06(H) = 12 s)
This value is the minimum time that the machine waits
before it dials the next destination.
Communication Switch 0F – Not used (do not change the settings.)
Communication Switch 10 (SP No. 1-104-017)
No
Function
Comments
0-7
Memory transmission: Maximum
number of dialing attempts to the
same destination
01 – FE (Hex) times
Communication Switch 11 – Not used (do not change the settings.)
Communication Switch 12 (SP No. 1-104-019)
No
Function
Comments
4. Service Tables
128
Содержание Type M12
Страница 1: ...Fax Option Type M12 Machine Code D3A5 Field Service Manual July 2014 Subject to change...
Страница 2: ......
Страница 10: ...8...
Страница 22: ...2 Remove the controller cover A x 4 3 Remove the controller rear cover A x 5 1 Installation 20...
Страница 28: ...Fax Unit Options Memory Unit Type M12 64MB 1 Remove the controller box cover x 4 1 Installation 26...
Страница 50: ...2 Replacement and Adjustment 48...
Страница 84: ...3 Troubleshooting 82...
Страница 218: ...5 Detailed Section Descriptions 216...
Страница 226: ...MEMO 224 EN...