
0-1
Inch-mm conversion before tx
Bit 1: 0, Bit 0: 0
= Inch-mm conversion available
Bit 1: 0, Bit 0: 1 = Inch only
Bit 1: 1, Bit 0: 0 = Not used
Bit 1: 1, Bit 0: 1 = Disabled
If "inch only" is selected on the machine uses inch-based
resolutions for scanning, the printed copy may be slightly
distorted at the other end if that machine uses mm-based
resolutions.
If the setting is "Inch-mm conversion available ", Inch-mm
conversion become effective to the special senders.
If the setting is "Disabled", the bit switch setting is used.
2-3
DIS/NSF detection method
Bit 3: 0, Bit 2: 0
= First DIS or NSF
Bit 3: 0, Bit 2: 1
= Second DIS or NSF
Bit 3: 1, Bit 2: 0 = Not used
Bit 3: 1, Bit 2: 1 = Disabled
(0, 1): Use this setting if echoes on the line are interfering
with the set-up protocol at the start of transmission. The
machine will then wait for the second DIS or NSF before
sending DCS or NSS.
If the setting is "Disabled", the bit switch setting is used.
4
V.8 protocol
0: Off
1: Disabled
If transmissions to a specific destination always end at a
lower modem rate (14,400 bps or lower), disable V.8
protocol so as not to use V.34 protocol.
0: V.34 communication will not be possible.
If the setting is "Disabled", the bit switch setting is used.
5
Compression modes available in
transmit mode
0: MH only
1: Disabled
This bit determines the capabilities that are informed to
the other terminal during transmission.
If the setting is "Disabled", the bit switch setting is used.
6-7
ECM during transmission
Bit 7: 0, Bit 6: 0 = Off
Bit 7: 0, Bit 6: 1 = On
Bit 7: 1, Bit 6: 0 = Not used
Bit 7: 1, Bit 6: 1 = Disabled
For example, if ECM is switched on but is not wanted
when sending to a particular terminal, use the (0, 0)
setting.
• V.8/V.34 protocol and JBIG compression are
automatically disabled if ECM is disabled.
• If the setting is "Disabled", the bit switch setting is
used.
Switch 04 - Not used (do not change the settings)
Switch 05 - Not used (do not change the settings)
Dedicated Transmission Parameters
179
Содержание Type M12
Страница 1: ...Fax Option Type M12 Machine Code D3A5 Field Service Manual July 2014 Subject to change...
Страница 2: ......
Страница 10: ...8...
Страница 22: ...2 Remove the controller cover A x 4 3 Remove the controller rear cover A x 5 1 Installation 20...
Страница 28: ...Fax Unit Options Memory Unit Type M12 64MB 1 Remove the controller box cover x 4 1 Installation 26...
Страница 50: ...2 Replacement and Adjustment 48...
Страница 84: ...3 Troubleshooting 82...
Страница 218: ...5 Detailed Section Descriptions 216...
Страница 226: ...MEMO 224 EN...